bioRxivBioinformaticsPreprint
Infarctsize-AI: an efficient infarct size image analysis tool for small rodent myocardial infarction studies
Csenger KovácsháziiD, Dóra Kapui, Bennet Y. WeberiD, T Gergely, Gábor B Brenner, Bence ÁggiD, Csanad Tabajdi, Adrienn Rácz, András HorváthiD, Sauri Hernández‐ReséndiziD, Derek John HausenloyiD, Reinis Vilšķe̅rstsiD, Marta OknińskaiD, Michał WaszkiewicziD, Michał Ma̧czewskiiD, Arnold Molnár, Tamara SzabadosiD, Péter BencsikiD, Thomas KriegiD, Javier InserteiD, Rainer SchulziD, Coert Jozef ZuurbieriD, Ioanna AndreadouiD, Bruno Karl PodesseriD, Péter FerdinándyiD, Zoltán GiricziD
Abstract
BackgroundMyocardial infarct size (IS) is the gold standard end-point in shorth-term studies on cardioprotection. However, IS quantification in rodent models with standard Evans Blue and 2,3,5-triphenyltetrazolium chloride (TTC) staining is time-consuming and prone to inter-observer variance. Therefore, we aimed to develop an artificial intelligence (AI)-based application to reduce time and inter-observer variability of IS analysis in rodent acute myocardial infarction (MI) models. MethodsWe used TTC/Evans blue-stained heart slice images of independent laboratories from previously published projects. Rat (n = 325 and 248 slices) and mouse (n = 77 slices) datasets were used to train deep learning segmentation models with three different neural network architectures, which were combined into a single AI analysis. AI analysis was compared with manual analysis on rat data from a training laboratory (internal data, n = 496 slices, n = 41 whole-hearts) and data from independent laboratories (external data, n = 60 and 62 slices). Additionally, two independent evaluators performed manual and AI-assisted analysis, consisting of AI-analysis and its manual correction, on internal (n = 36 slices) and external data (n = 37 slices). ResultsLins concordance correlation coefficient (CCC) between IS/AAR values from manual and AI analysis was 0.844 with 95% CI of [0.814; 0.869] for images of internal data heart slices. On external data heart slices, AI accurately annotated slice area and AAR but failed to annotate infarcted area. On internal whole-heart data, CCC between AI and AI-assisted IS/AAR was 0.894 with 95% CI of [0.812; 0.942]. AI-assisted analysis reduced evaluation time on both internal and external datasets and increased region overlap for AAR between the two independent evaluators on dependent data. ConclusionsAI-assisted analysis significantly reduced analysis time and inter-observer variability. For optimal performance, lab-specific AI training is recommended. Infarctsize-AI is available at https://infarctsize.com. Translational perspectiveMyocardial infarct size (IS) is the gold-standard end-point in shorth-term studies to assess potential cardioprotective therapies against acute myocardial infarction (AMI). However, IS quantification in rodent AMI models is time-consuming and prone to inter-observer variance. Therefore, we developed an AI-based software that can reduce analysis time and inter-observer variability and facilitate documentation, which facilitates the clinical translation of potential cardioprotective therapies. Graphical abstract O_FIG O_LINKSMALLFIG WIDTH=200 HEIGHT=34 SRC="FIGDIR/small/688527v1_ufig1.gif" ALT="Figure 1"> View larger version (15K): org.highwire.dtl.DTLVardef@187c938org.highwire.dtl.DTLVardef@1ab8bb4org.highwire.dtl.DTLVardef@160dc68org.highwire.dtl.DTLVardef@264617_HPS_FORMAT_FIGEXP M_FIG C_FIG
- organism: rat
- organism: mouse
- assay: imaging
- research focus: cell type annotation
- research focus: clustering
- research focus: dimensionality reduction
- approach: deep learning
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Convolutional neural networks for automated CMR image segmentation in rats with myocardial infarcts
A. Gondova, M. Zurek, … E. Watson·bioRxiv·Dec 1, 2020
- Novel fluorescence-based methods to determine infarct and scar size in murine models of reperfused myocardial infarction
Ashley Duplessis, Christin Elster, … Norbert Gerdes·CellsPeer-reviewed·Sep 30, 2024
- INCLUSION CRITERIA UPDATE OF THE INTRALUMINAL ISCHEMIC MODEL IN RAT FOR PRECLINICAL STUDIES
Héctor Fernández‐Susavila, Ramón Iglesias‐Rey, … Francisco Campos·Disease Models & MechanismsPeer-reviewed·Dec 1, 2017
- Detection, Isolation and Quantification of Myocardial Infarct with Four Different Histological Staining Techniques
Xiaobo Wu, Linnea Elisabeth Bornkast Meier, … Robert G. Gourdie·DiagnosticsPeer-reviewed·Oct 18, 2024
- Excellent agreement between automated deep learning-based and manual DWI infarct volume measurement in hyperacute stroke
Yuki Sakamoto, Junya Aoki, … Satoshi Suda·bioRxiv·Dec 19, 2025
- Multi-Modality Deep Infarct: Non-invasive identification of infarcted myocardium using composite in-silico-human data learning