Impedance scaling for gold and platinum microelectrodes
B. Fan, B. Wolfrum, J. Robinson
This paper investigates how impedance scales with electrode area for gold and platinum microelectrodes, finding that platinum impedance transitions from area-based to perimeter-based scaling below 10 microns.
Journal of Neural Engineering · Sep 9, 2021Peer-reviewedBioengineering