Abstract
ObjectiveThis article presents a novel transcranial magnetic stimulation (TMS) pulse generator with a wide range of pulse shape, amplitude, and width. ApproachBased on a modular multilevel TMS (MM-TMS) topology we had proposed previously, we realized the first such device operating at full TMS energy levels. It consists of ten cascaded H-bridge modules, each implemented with insulated-gate bipolar transistors, enabling both novel high-amplitude ultrabrief pulses as well as pulses with conventional amplitude and duration. The MM-TMS device can output pulses including up to 21 voltage levels with a step size of up to 1100 V, allowing relatively flexible generation of various pulse waveforms and sequences. The circuit further allows charging the energy storage capacitor on each of the ten cascaded modules with a conventional TMS power supply. Main resultsThe MM-TMS device can output peak coil voltages and currents of 11 kV and 10 kA, respectively, enabling suprathreshold ultrabrief pulses (> 8.25 s active electric field phase). Further, the MM-TMS device can generate a wide range of near-rectangular monophasic and biphasic pulses, as well as more complex staircase-approximated sinusoidal, polyphasic, and amplitude-modulated pulses. At matched estimated stimulation strength, briefer pulses emit less sound, which could enable quieter TMS. Finally, the MM-TMS device can instantaneously increase or decrease the amplitude from one pulse to the next in discrete steps by adding or removing modules in series, which enables rapid pulse sequences and paired-pulse protocols with variable pulse shapes and amplitudes. SignificanceThe MM-TMS device allows unprecedented control of the pulse characteristics which could enable novel protocols and quieter pulses.
02 /Specification & Classification
Click any tag to browse matching papers- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Low-cost monophasic transcranial magnetic stimulator
Maxence Lapatrie, Yuzuha Isetani, … Milica Popović·bioRxiv·Aug 26, 2026
- A Neurostimulator System for Real, Sham, and Multi-Target Transcranial Magnetic Stimulation
M. Memarian Sorkhabi, T. Denison·bioRxiv·Nov 22, 2021
- Pulse-Width Modulation-based TMS mimics effects of conventional TMS on human primary motor cortex
Majid Memarian Sorkhabi, Karen Wendt, … Timothy Denison·bioRxiv·Nov 24, 2021
- Optimized Monophasic Pulses with Equivalent Electric Field for Rapid-Rate Transcranial Magnetic Stimulation
B. Wang, J. Zhang, … S. M. Goetz·bioRxiv·Aug 29, 2022
- Optimisation of asymmetric field pulses for transcranial magnetic stimulation
Ke Ma, Stephan M. Goetz·bioRxiv·May 1, 2023
- Low Intensity Multi-Channel Steering TMS Array for Network Level Neuromodulation
Dexuan Tang, Corey Swenson, … Sergey N Makaroff·bioRxiv·Aug 25, 2026