Mathematical models can be used to generate high-fidelity simulations of the cardiopulmonary system. Such models, when applied to real patients, can provide valuable insights into underlying physiological processes that are hard for clinicians to observe directly. In this work, we propose a novel modelling strategy capable of generating scenario-specific cardiopulmonary simulations to replicate the vital physiological signals clinicians use to determine the state of a patient. This model is composed of a tree-like pulmonary system that features a novel, non-linear alveoli opening strategy, based on the dynamics of balloon inflation, that interacts with the cardiovascular system via the thorax. A baseline simulation of the model is performed to measure the response of the system during spontaneous breathing which is subsequently compared to the same system under mechanical ventilation. To test the new lung opening mechanics and systematic recruitment of alveolar units, a positive end-expiratory pressure (PEEP) test is performed and its results are then compared to simulations of a deep spontaneous breath. The system displays a marked decrease in tidal volume as PEEP increases, replicating a sigmoidal curve relationship between volume and pressure. At high PEEP, cardiovascular function is shown to be visibly impaired, in contrast to the deep breath test where normal function is maintained.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 6
- FWCI
- 1.63
- Field percentile
- top 18%
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Human circulatory system response to changes in alveolar pressure and lung volume
Yu. S. Semenov, A. I. Dyachenko, … R. N. Zaripov·bioRxiv·Mar 16, 2024
- Whole-body plethysmography revisited
S. Hülsmann, A. Khan, … C. Dullin·bioRxiv·Feb 24, 2021
- Aeration Strategy at Birth Does Not Impact Carotid Blood Flow and Oxygen Delivery in Preterm Lambs
- Predictive vascular growth and remodeling in pulmonary hypertension: simulating intervention effects from captured evolution
Faeze Jahani, Brett Cardenas, … Jason M. Szafron·bioRxiv·Aug 9, 2026
- A multiscale model of the cardiovascular system that regulates arterial pressure via closed loop baroreflex control of chronotropism, cell-level contractility, and vascular tone
H. Sharifi, C. K. Mann, … K. Campbell·bioRxiv·Oct 21, 2021
- A Micro-scale Humanized Ventilator-on-a-Chip to Examine the Injurious Effects of Mechanical Ventilation
Basia Gabela-Zuniga, Vasudha C. Shukla, … Samir N. Ghadiali·Lab on a ChipPeer-reviewed·Jan 1, 2024