Ablation catheter motion detection during contact force and VISITAG™ Module-guided pulmonary vein isolation
D. R. Tomlinson, K. Biscombe, J. True, J. Hosking, A. J. Streeter
Abstract
BackgroundDuring contact force (CF) and VISITAG Module (Biosense Webster) guided pulmonary vein isolation (PVI), ACCURESP respiratory motion adjustment is recommended, although without in vivo validation.\n\nObjectiveSince accurate LAPW radiofrequency (RF) annotation is crucial to avoid oesophageal thermal injury, we compared ACCURESP setting (\"on\" versus \"off\") on RF annotation at the left atrial posterior wall (LAPW).\n\nMethodsFrom a twenty-five patient cohort undergoing CF PVI (continuous RF, 30W) using general anaesthesia and VISITAG Module annotation-guidance (force-over-time 100% minimum 1g, 2mm position stability, ACCURESP \"off\"), respiratory motion detection occurred in eight, permitting retrospective comparison of ACCURESP settings.\n\nResultsThere were significant differences in LAPW RF data annotation according to ACCURESP setting. Comparing ACCURESP \"on\" versus \"off\", respectively: Total annotated sites 82 versus 98; Median RF duration per-site 13.3s versus 10.6s (p<0.0001); Median force time integral 177g.s versus 130g.s (p=0.0002); Mean inter-lesion distance (ILD) 6.0mm versus 4.8mm (p=0.002). Considering only annotated site 1-to-2 transitions, three occurred with 0g CF; ACCURESP \"on\" minus \"off\" difference in RF duration was <0.6s. However, thirteen site 1-to-2 transitions during constant catheter-tissue contact (ILD range 2.1 - 7.0mm) demonstrated a mean difference in annotated RF duration at site 1, of 3.7s (Range: -1.3 - 11.3s). Reconstituted curves displaying catheter position data, CF, impedance and site 1-to-2 transition according to ACCURESP setting, demonstrated multiple markers of catheter movement coinciding with ACCURESP \"off\".\n\nConclusionsACCURESP \"off\" setting demonstrated excellent catheter movement detection properties and represents an optimal method towards the annotation of stable sites of RF delivery at the LAPW.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Assessment of the transmural unipolar electrogram morphology change radius during contact force-guided pulmonary vein isolation using the VISITAG™ Module and CARTOREPLAY™
David R. Tomlinson, Kara N. Stevens, Adam J. Streeter·bioRxiv·Mar 19, 2018
- Transmural unipolar electrogram morphology is achieved within 7s at the posterior left atrial wall during pulmonary vein isolation: VISITAG™ Module-based lesion assessment during radiofrequency ablation
D. Tomlinson, M. Myles, … A. J. Streeter·bioRxiv·Dec 15, 2017
- Derivation and validation of a VISITAG™-guided contact force ablation protocol for pulmonary vein isolation
David R. Tomlinson·bioRxiv·Dec 13, 2017
- Ablation Of Complex Fractionated Electrograms Improves Outcome In Long Standing Persistent Atrial Fibrillation
Claire Martin, James P. Curtain, … Sharad Agarwal·bioRxiv·Apr 3, 2017
- Comparison of therapeutic effects between pulsed field ablation and cryoballoon ablation in the treatment of atrial fibrillation: a systematic review and me-ta-analysis
Yun Wan, Shuting Zeng, … Jun Luo·Cardiology in ReviewPeer-reviewed·Nov 14, 2024
- Cardiac-Gated Spectroscopic Photoacoustic Imaging for Ablation-Induced Necrotic Lesion Visualization: In Vivo Demonstration in a Beating Heart
S. Gao, H. Ashikaga, … H. K. Zhang·bioRxiv·May 23, 2022