bioRxivSystems BiologyPreprint
Ablation Of Complex Fractionated Electrograms Improves Outcome In Long Standing Persistent Atrial Fibrillation
Claire MartiniD, James P. CurtainiD, Parag Ravindra GajendragadkariD, David BegleyiD, Simon P. FynniD, Andrew A. GraceiD, Patrick M. HeckiD, Munmohan Virdee, Sharad AgarwaliD
Abstract
PurposeThere is controversy and sparse data on whether substrate based techniques in addition to pulmonary vein isolation (PVI) confer benefit in the catheter ablation of persistent atrial fibrillation (AF), especially if long standing. We performed an observational study to assess whether substrate based ablation improved freedom from atrial arrhythmia.\n\nMethods286 patients undergoing first ablation procedures for persistent AF with PVI only, PVI plus linear ablation, or PVI plus complex fractionated electrogram (CFAE) and linear ablation were followed. Primary end point was freedom from atrial arrhythmia at one year.\n\nResultsMean duration of pre-procedure time in AF was 28+/-27 months. Freedom from atrial arrhythmia was higher with a PVI+CFAE+lines strategy then for PVI alone (HR 1.56, 95% CI: 1.04-2.34, p=0.032) but was not higher with PVI+lines. Benefit of substrate modification was conferred for pre-procedure times in AF of over 30 months. The occurrence of atrial tachycardia was higher when lines were added to the ablation strategy (HR 0.08, 95% CI: 0.01-0.59, p=0.014). Freedom from atrial arrhythmia at 1 year was higher with lower patient age, use of general anaesthetic (GA), normal or mildly dilated left atrium and decreasing time in AF.\n\nConclusionsIn patients with long standing persistent AF of over 30 months duration, CFAE ablation resulted in improved freedom from atrial arrhythmia. Increased freedom from atrial arrhythmia occurs in patients who are younger and have smaller atria, and with GA procedures. Linear ablation did not improve outcome and resulted in a higher incidence of atrial tachycardia.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Comparison of therapeutic effects between pulsed field ablation and cryoballoon ablation in the treatment of atrial fibrillation: a systematic review and me-ta-analysis
Yun Wan, Shuting Zeng, … Jun Luo·Cardiology in ReviewPeer-reviewed·Nov 14, 2024
- Improved Outcome And Cost Effectiveness In Ablation Of Persistent Atrial Fibrillation Under General Anaesthetic
Claire Martin, James P. Curtain, … Sharad Agarwal·EP EuropacePeer-reviewed·Apr 21, 2017
- Derivation and validation of a VISITAG™-guided contact force ablation protocol for pulmonary vein isolation
David R. Tomlinson·bioRxiv·Dec 13, 2017
- Regions of Highly Recurrent Electrogram Morphology at Sites of Low Cycle Length Accurately Reflect Arrhythmogenic Substrate for Atrial Fibrillation - Implications For a New, Mechanism Guided Therapeutic Approach for Atrial Fibrillation
S. Yoo, M. Rottmann, … R. Arora·bioRxiv·Dec 10, 2020
- Transmural unipolar electrogram morphology is achieved within 7s at the posterior left atrial wall during pulmonary vein isolation: VISITAG™ Module-based lesion assessment during radiofrequency ablation
D. Tomlinson, M. Myles, … A. J. Streeter·bioRxiv·Dec 15, 2017
- Rapid Shift Toward Pulsed Field Ablation and Precision Risk Stratification in High-Impact Atrial Fibrillation Research
Zheng Su, Tinsley Li·bioRxiv·Sep 18, 2026