Metric-driven Pre-acquisition Diagnostics for Automated Microscopy Ultraviolet Surface Excitation (MUSE)
Abstract
Background Automated microscopy enables large-scale tiled imaging but remains sensitive to variations in alignment, illumination, focus, and sample coverage that may only be detected after acquisition. We present an adaptive pre-acquisition quality-control framework for microscopy ultraviolet surface excitation (MUSE) that uses sparse scout imaging and tile-level metrics to guide acquisition and selective rescanning. Methods The framework quantifies brightness, dynamic range, focus, tissue fraction, and exposure error across the field of view. For example, in a representative 10 x 10 acquisition (100 tiles, 20-megapixel imagery), the mean p99 brightness was 0.525 (CV 10.4%), the mean dynamic range was 0.331, the median focus score was 0.0333, and the median tissue fraction was 0.943. Furthermore, applying a conservative exposure-error threshold (|error| > 0.25) identified 25% of tiles as rescan candidates. Results These results show that compact tile-level metrics can be converted into actionable quality gates, enabling early detection of local acquisition errors and targeted rescanning to improve mosaic consistency while minimizing unnecessary acquisition.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Pocket MUSE: an affordable, versatile and high performance fluorescence microscope using a smartphone
Y. Liu, A. M. Rollins, … M. W. Jenkins·bioRxiv·Aug 28, 2020
- Long-term quality assessment and monitoring of light microscope performance through accessible and reliable protocols, tools and metrics
O. Faklaris, L. Bancel-Vallee, … T. Guilbert·bioRxiv·Jun 16, 2021
- Consequences of the Nyquist-Shannon sampling criterion in Mesoscopic Multiphoton Microscopy to avail full-field sub-micron resolution resolvability
B. J. Borah, J.-C. Lee, … C.-K. Sun·bioRxiv·Jan 31, 2021
- Design Principles for Autonomous Illumination Control in Localization Microscopy
- An open-source, high resolution, automated fluorescence microscope
A. C. Zehrer, A. Martin-Villalba, … H. Ewers·bioRxiv·May 31, 2023
- Enhanced super-resolution microscopy by combined Airyscan and Quantum-Dot-Triexciton Imaging
S. Hennig, D. J. Manstein·bioRxiv·May 7, 2020