Fluidic Microactuation of Flexible Electrodes for Neural Recording
Flavia VitaleiD, Daniel G. VercosaiD, Alexander V. RodrigueziD, Sushma Sri PamulapatiiD, Frederik SeibtiD, Eric Lewis, J. Stephen YaniD, Krishna N. BadhiwalaiD, Mohammed AdnaniD, Gianni Royer CarfagniiD, Michael BeierleiniD, Caleb T. KemereiD, Matteo Pasquali AiD, Jacob T. RobinsoniD
Abstract
Ultra-flexible microelectrodes that can bend and flex with the natural movement of the brain reduce the inflammatory response and improve the stability of long-term neural recordings.1-5 However, current methods to implant these highly flexible electrodes rely on temporary stiffening agents that increase the electrode size6-10 thus aggravating neural damage during implantation, which leads to cell loss and glial activation that persists even after the stiffening agents are removed or dissolve.11-13 A method to deliver thin, ultra-flexible electrodes deep into neural tissue without increasing the stiffness or size of the electrodes will enable minimally invasive electrical recordings from within the brain. Here we show that specially designed microfluidic devices can apply a tension force to ultra-flexible electrodes that prevents buckling without increasing the thickness or stiffness of the electrode during implantation. Additionally, these \"fluidic microdrives\" allow us to precisely actuate the electrode position with micron-scale accuracy. To demonstrate the efficacy of our fluidic microdrives, we used them to actuate highly flexible carbon nanotube fiber (CNTf) microelectrodes11,14 for electrophysiology. We used this approach in three proof-of-concept experiments. First, we recorded compound action potentials in a soft model organism, the small cnidarian Hydra. Second, we targeted electrodes precisely to the thalamic reticular nucleus in brain slices and recorded spontaneous and optogenetically-evoked extracellular action potentials. Finally, we inserted electrodes more than 4 mm deep into the brain of rats and detected spontaneous individual unit activity in both cortical and subcortical regions. Compared to syringe injection, fluidic microdrives do not penetrate the brain and prevent changes in intracranial pressure by diverting fluid away from the injection site during insertion and actuation. Overall, the fluidic microdrive technology provides a robust new method to implant and actuate ultra-flexible neural electrodes.
- organism: human
- organism: rat
- organism: mouse
- assay: electronic health records
- research focus: drug response / drug discovery
- research focus: benchmarking
- research focus: database / resource
- research focus: software / tool
- approach: experimental assay
- Citations
- 113
- FWCI
- 5.35
- Field percentile
- top 3%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Stiffness-tunable neurotentacles for minimally invasive implantation and long-term neural activity recordings
Yang Wang, Xing Xu, … Weihua Pei·Advanced SciencePeer-reviewed·Jul 21, 2025
- MEMS-Actuated Carbon Fiber Microelectrode for Neural Recording
R. S. Zoll, C. B. Schindler, … K. S. J. Pister·bioRxiv·Oct 12, 2018
- Repeatable, low-drift recordings in behaving non-human primates using flexible microelectrodes
Daniel P. Woods, Grace Adams, … Daniel L. Gonzales·Nature CommunicationsPeer-reviewed·Sep 9, 2026
- Mechanical flexibility reduces the foreign body response to long- term implanted microelectrodes in rabbit cortex
Harbaljit S Sohal, Gavin J Clowry, … Stuart N Baker·bioRxiv·Jun 14, 2016
- Microfluidics for Electrophysiology, Imaging, and Behavioral Analysis of Hydra
Krishna N. Badhiwala, Daniel L. Gonzales, … Jacob T. Robinson·Lab on a ChipPeer-reviewed·Jan 1, 2018
- The \"sewing machine\" for minimally invasive neural recording
Timothy Hanson, Camilo A. Diaz-Botia, … Philip N. Sabes·bioRxiv·Mar 14, 2019