T1-weighted fMRI in mouse visual cortex using an Iron Oxide Nanoparticle contrast agent and Ultrashort Echo Time (UTE) imaging at 9.4 T
Naman Vijaykumar JainiD, Saskia BollmanniD, Kai‐Hsiang ChuangiD, Jon̈athan R. PolimeniiD, Markus BarthiD
Abstract
PurposeThis study aims to investigate the feasibility of using T1-weighted fMRI with an iron oxide nanoparticle contrast agent and Ultrashort Echo Time (UTE) imaging at 9.4T to measure functional hyperaemia in the mouse visual cortex. The goal is to capture positive signal changes in both the parenchyma and pial surface, and to test whether surface vessels respond during neuronal activation. MethodsThe study involved scanning of nine mice after administration of iron oxide-based superparamagnetic contrast agent (Molday ION) via the tail vein. Two functional imaging experiments were conducted: one to investigate the effect of echo time on the functional response, and another to characterize the impact of higher resolution on UTE functional contrast. Regions of interest (ROIs) were defined in the parenchyma and pial surface of the visual cortex. ResultsThe administration of the contrast agent produced a bright-blood signal in the vasculature in structural MRI when using a UTE acquisition. Positive signal changes were observed at the shortest echo time (0.164 ms) in both the parenchyma (0.2% {+/-} 0.08) and pial surface (0.2% {+/-} 0.1 %), providing evidence that UTE fMRI experiments can detect changes in both pial and parenchymal vessels. Measurements using longer echo times ([≥]1 ms) showed negative signal changes. Higher spatial resolution resulted in increased percent signal change at the pial surface, suggesting less partial volume effects and better delineation of surface vessels. ConclusionThe findings demonstrate that T1-weighted fMRI with UTE imaging and iron oxide nanoparticles captures positive signal changes across all vascular compartments, providing additional insights into the involvement of surface vessels during functional hyperemia.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multi-modal microvascular cerebral blood flow velocity mapping with 14T single-vessel MRI and optical microscopy in the mouse brain
D. R. Miller, X. A. Zhou, … S. Sakadzic·bioRxiv·Nov 7, 2023
- A critical assessment of data quality and venous effects in ultra-high-resolution fMRI
Kendrick Kay, Keith Wakefield Jamison, … Kǎmil Uǧurbil·NeuroImagePeer-reviewed·Feb 5, 2019
- High-Resolution 3D Ultra-Short Echo Time MRI with Rosette k-Space Pattern for Brain Iron Content Mapping
Xin Shen, Ali Çağlar Özen, … Uzay E. Emir·bioRxiv·Aug 24, 2022
- Visual stimulus-evoked blood velocity responses in individual human posterior cerebral arteries measured with dynamic phase-contrast functional MR angiography
Zhangxuan Hu, Sébastien Proulx, … Jon̈athan R. Polimeni·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- Validating layer-specific VASO across species
Laurentius Huber, Benedikt Andreas Poser, … Aneurin J. Kennerley·NeuroImagePeer-reviewed·May 24, 2021
- Spanning spatial scales with functional imaging in the human brain; initial experiences at 10.5 Tesla
Luca Vizioli, Lasse Knudsen, … Kǎmil Uǧurbil·bioRxiv·Dec 20, 2024