Cardiac toxicity predictions: Safety pharmacologists correlate with the CiPA model
Abstract
There has been a lot of interest and publicity regarding the use of a complex biophysical model within drug development for predicting the TdeP risk of new compounds. Throughout the development of the complex model numerous groups have shown that a simple linear mechanistic model explains the predictive behaviour of complex mechanistic models. That is the input-output relationship is almost linear even when complex kinetic assays are used. We hypothesized that given this linear relationship that scientist would be able to predict the outcome of the biophysical model. The objective of this pilot study was to assess the feasibility of such an analysis but also assess the initial degree of correlation. A set of 15 compounds with diverse ion-channel blocking against 4 ion-channel currents, IKr, ICaL, INa and INaL, was generated. Safety pharmacologists across numerous companies were approached and asked to categorize the TdeP risk of these compounds using only the % block depicted via a bar chart into one of 3 categories: Risk, No-risk or Unsure. 12 scientists participated in the study, of which 11 correlated strongly with the model (11 person ROC AUC range: 0.86-1, 7 scientists had a value >0.9). The combined prediction of all scientists also correlated strongly with the model. These results highlight that the linear input-output relationship can indeed be predicted by the scientist. A future study exploring the degree of correlation with a wider group of scientists and wider set of compounds would be required to get a more precise estimate of the correlation. We hope this initial exploratory study will encourage the community to pursue this idea.Competing Interest StatementThe authors have declared no competing interest.View Full Text
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Complex versus simple models: ion-channel cardiac toxicity prediction
H. Mistry·bioRxiv·Oct 20, 2017
- Intrinsic structure of model-derived metrics for in silico proarrhytmic risk assessment identified by global sensitivity analysis
J. Parikh, P. Di Achille, … V. Gurev·bioRxiv·Apr 16, 2019
- Comparison of in silico predictions of action potential duration in response to inhibition of IKr and ICaL with new human ex vivo recordings
Yann-Stanislas H. M. Barral, Liudmila Polonchuk, … Ken Wang·bioRxiv·Feb 26, 2025
- Prediction of TdP Arrhythmia Risk Through Molecular Simulations of Conformation-specific Drug Interactions with the hERG K+, NaV1.5, and CaV1.2 Channels
Kyle C. Rouen, Kush Narang, … Igor V. Vorobyov·bioRxiv·Sep 25, 2025
- A computational pipeline to predict cardiotoxicity:From the atom to the rhythm
Pei‐Chi Yang, Kevin R. DeMarco, … Colleen E. Clancy·Circulation ResearchPeer-reviewed·Mar 18, 2020
- Early afterdepolarisation tendency as a simulated pro-arrhythmic risk indicator
B. McMillan, D. J. Gavaghan, G. Mirams·bioRxiv·Aug 15, 2017