PLoS ONEMolecular BiologyPeer-reviewed journal article
Method comparison studies of telomere length measurement using qPCR approaches: a critical appraisal of the literature
Alyssa R. LindroseiD, Lauren W. Y. McLester‐DavisiD, Renee Isabella TristanoiD, Leila Kataria, Shahinaz M. GadallaiD, Dan T. A. EisenbergiD, Simon VerhulstiD, Stacy S. DruryiD
Abstract
Use of telomere length (TL) as a biomarker for various environmental exposures and diseases has increased in recent years. Various methods have been developed to measure telomere length. PCR-based methods remain wide-spread for population-based studies due to the high-throughput capability. While several studies have evaluated TL measurement methods, the results have been variable. We conducted a literature review of TL measurement cross-method comparison studies that included a PCR-based method published between January 1, 2002 and May 25, 2020. A total of 25 articles were found that matched the inclusion criteria. Papers were reviewed for quality of methodologic reporting of sample and DNA quality, PCR assay characteristics, sample blinding, and analytic approaches to determine final TL. Overall, methodologic reporting was low as assessed by two different reporting guidelines for qPCR-based TL measurement. There was a wide range in the reported correlation between methods (as assessed by Pearsons r) and few studies utilized the recommended intra-class correlation coefficient (ICC) for assessment of assay repeatability and methodologic comparisons. The sample size for nearly all studies was less than 100, raising concerns about statistical power. Overall, this review found that the current literature on the relation between TL measurement methods is lacking in validity and scientific rigor. In light of these findings, we present reporting guidelines for PCR-based TL measurement methods and results of analyses of the effect of assay repeatability (ICC) on statistical power of cross-sectional and longitudinal studies. Additional cross-laboratory studies with rigorous methodologic and statistical reporting, adequate sample size, and blinding are essential to accurately determine assay repeatability and replicability as well as the relation between TL measurement methods.
- Citations
- 89
- FWCI
- 8.63
- Field percentile
- top 1%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Effects of DNA extraction, DNA integrity, and laboratory on the precision of qPCR-based telomere length measurement - a multi-lab impartial study
Jue Lin, Simon Verhulst, … Stacy S. Drury·bioRxiv·Dec 14, 2022
- Universal assay for measuring vertebrate telomeres by real-time quantitative PCR
Stephanie Fern Hudon, Esteban Palencia Hurtado, … Eric J. Hayden·bioRxiv·Jan 28, 2020
- A Synthetic Single-Stranded Dual-Template Oligonucleotide as a Reference Standard for Monochrome Multiplex qPCR Measurements of Average Telomere Length
Richard Cawthon·bioRxiv·Jun 24, 2020
- Novel Dual Labeled Fluorescence Probe Based Assay to Measure the Telomere Length
Itty Sethi, Gh. Rasool Bhat, … Swarkar Sharma·GenePeer-reviewed·Sep 30, 2020
- Telomerecat: A Ploidy-Agnostic Method For Estimating Telomere Length From Whole Genome Sequencing Data
James H. R. Farmery, Mike L. Smith, … Emma L. Wakeling·Scientific ReportsPeer-reviewed·Jan 16, 2018
- Cross-tissue comparison of telomere length and quality metrics of DNA among individuals aged 8 to 70 years
Sarah E. Wolf, Waylon James Hastings, … Idan Shalev·PLoS ONEPeer-reviewed·Feb 22, 2024