Chlorine dioxide gas sterilization of cold-chain or temperature-sensitive devices
Abstract
Cold-chain terminal sterilization is used for products that must be manufactured, stored, and maintained with a carefully controlled temperature range, such as temperature-sensitive drugs and vaccines in prefilled syringes or autoinjectors containing temperature-sensitive drugs. Chlorine dioxide (ClO2) is an ideal sterilant for cold-chain terminal sterilization because it forms a true gas at room temperatures (15{degrees}C/59{degrees}F - 25{degrees}C/77{degrees}F), with a reliable and consistent process with excellent penetration and does not require elevated temperatures. In the current study, we validated the efficacy of ClO2 on cold stored pre-filled syringes as well as tested ClO2-sterilized samples and non-sterilized controls for residual sterilant on the prefilled syringe samples and the ingress of sterilant into the prefilled syringe samples. Residual sterilant remaining on a load after sterilization could cause chemical exposure to patients and negatively affect healthcare worker safety, among other things. Sterilant ingress into a medication could result in chemical contamination, drug degradation, and changes to drug formulation. Few studies have been published on ClO2 residue or ingress during terminal sterilization. We demonstrate that chlorine dioxide sterilization leaves residuals and ingress amounts at acceptably low levels. ClO2 sterilization is an excellent alternative to ethylene oxide sterilization for cold-chain sterilization because it is sustainable, non-carcinogenic, and does not leave harmful residuals, nor does it ingress into the drug product.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 1
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluation of the antiviral effect of chlorine dioxide (ClO2) using a vertebrate model inoculated with avian coronavirus
X. Zambrano-Estrada, C. A. Dominguez-Sanchez, … K. Acevedo-Whitehouse·bioRxiv·Oct 13, 2020
- Heat Stable and Intrinsically Sterile Liquid Protein Formulations
Atip Lawanprasert, Harminder Singh, … Scott H. Medina·Nature CommunicationsPeer-reviewed·Dec 30, 2024
- Stability of SARS-CoV-2 in cold-chain transportation environments and the efficacy of disinfection measures
- A Thermostable Tetanus/diphtheria (Td) Vaccine in the Stablevax™ Pre-Filled Delivery System
B. Roser, J. de la Torre Arrieta, … I. Garcia de Castro·bioRxiv·Feb 16, 2023
- Deactivation of SARS-CoV-2 surrogate porcine epidemic diarrhea virus with electron beam irradiation under the cold chain transportation condition
- Thermal Fogging with Disinfectant Didecyl Dimethyl Ammonium Bromide Effectively Kills A Coronavirus, An Influenza Virus and Two Indicator Bacteria in Subzero Cold-Chain Environment
Qiaoyun Hu, Pei Ma, … Zhengjun Yu·bioRxiv·Mar 25, 2021