bioRxivNeurosciencePreprint
Uncovering and mitigating bias in large, automated MRI analyses of brain development
Safia Elyounssi, Keiko KunitokiiD, Jacqueline Alexandra ClaussiD, Eline Laurent, Kristina A. Kane, Dylan HughesiD, Casey E. HopkinsoniD, Oren M. Bazer, Rachel Freed SussmaniD, Alysa E. DoyleiD, Hang LeeiD, Brenden Tervo‐ClemmensiD, Hamdi EryilmaziD, Randy L. GollubiD, Deanna M. BarchiD, Theodore Daniel SatterthwaiteiD, Kevin F. DowlingiD, Joshua L. RoffmaniD
Abstract
Large, population-based MRI studies of adolescents promise transformational insights into neurodevelopment and mental illness risk 1, 2. However, MRI studies of youth are especially susceptible to motion and other artifacts 3, 4. These artifacts may go undetected by automated quality control (QC) methods that are preferred in high-throughput imaging studies, 5 and can potentially introduce non-random noise into clinical association analyses. Here we demonstrate bias in structural MRI analyses of children due to inclusion of lower quality images, as identified through rigorous visual quality control of 11,263 T1 MRI scans obtained at age 9-10 through the Adolescent Brain Cognitive Development (ABCD) Study6. Compared to the best-rated images (44.9% of the sample), lower-quality images generally associated with decreased cortical thickness and increased cortical surface area measures (Cohens d 0.14-2.84). Variable image quality led to counterintuitive patterns in analyses that associated structural MRI and clinical measures, as inclusion of lower-quality scans altered apparent effect sizes in ways that increased risk for both false positives and negatives. Quality-related biases were partially mitigated by controlling for surface hole number, an automated index of topological complexity that differentiated lower-quality scans with good specificity at Baseline (0.81-0.93) and in 1,000 Year 2 scans (0.88-1.00). However, even among the highest-rated images, subtle topological errors occurred during image preprocessing, and their correction through manual edits significantly and reproducibly changed thickness measurements across much of the cortex (d 0.15-0.92). These findings demonstrate that inadequate QC of youth structural MRI scans can undermine advantages of large sample size to detect meaningful associations.
- Citations
- 14
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Variations in Structural MRI Quality Significantly Impact Commonly-Used Measures of Brain Anatomy
Alysha D. Gilmore, Nicholas J. Buser, Jamie Lars Hanson·Brain InformaticsPeer-reviewed·Apr 15, 2021
- Data-driven Assessment of Structural Image Quality
Adon F.G. Rosen, David R. Roalf, … Theodore Daniel Satterthwaite·NeuroImagePeer-reviewed·Dec 24, 2017
- Data quality biases normative models derived from fetal brain MRI
Thomas Sanchez, Angeline Mihailov, … Guillaume Auzias·Imaging NeurosciencePeer-reviewed·Jan 1, 2026
- Image processing and analysis methods for the Adolescent Brain Cognitive Development Study
Donald J. Hagler, Sean N. Hatton, … Scott Peltier·NeuroImagePeer-reviewed·Aug 12, 2019
- Structural brain development: a review of methodological approaches and best practices
N. Vijayakumar, K. L. Mills, … S. Whittle·bioRxiv·Jun 23, 2017
- Highly replicable multisite patterns of adolescent white matter maturation
Steven L. Meisler, Matthew Cieslak, … Theodore Daniel Satterthwaite·bioRxiv·Apr 19, 2026