Journal of Synchrotron RadiationBiophysicsPeer-reviewed journal article
Multifunctional bending magnet beamline with a capillary optic for X-ray fluorescence studies of metals in tissue sections
Benjamin RoteriD, Andrew M. CrawfordiD, Qiaoling JiniD, Arthur Glowacki, Barry Chi Hong LaiiD, Fabricio Marin, Evan MaxeyiD, Xianbo ShiiD, Valeria CulottaiD, Asia S. WildemaniD, Naisargi K. PateliD, Thomas V. O’HalloraniD, Chris J. JacobseniD
Abstract
Scanning fluorescence X-ray microscopy lets one non-destructively and quantitatively map the distribution of most biologically-important metals in cells and tissues. For studies on large-scale tissues and organs, a spatial resolution of several micrometers is often sufficient; in this case, bending magnets at synchrotron light sources provide abundant X-ray flux. We describe here the use of bending magnet beamline 8-BM-B at the Advanced Photon Source (APS) with two distinct microscopy stations: a pre-existing one with Kirkpatrick-Baez (KB) mirror optics for slightly higher throughput and the ability to accommodate samples tens of centimeters across, and a new prototype station with an axially-symmetric, single-bounce, capillary optic with slightly less flux, but slightly higher fluence (which affects achievable resolution at low metal concentration) and higher spatial resolution. The KB station provides{delta} res = 10.5 {micro}m spatial resolution at a per-pixel exposure time of tdwell = 100 ms and a fluence per time of 5.8x 107 photons /({micro}m2 {middle dot}s), while the prototype capillary station provides{delta} res = 6.3 {micro}m at tdwell = 50 ms and a fluence per time of 6.1x 107 photons ({micro}m2 {middle dot}s). We used image power spectral density to estimate the achieved spatial resolution{delta} res from individually acquired images, with{delta} res depending-on the optic, the fluorescence signal strength of the sample being imaged, and the method used to process raw fluorescence spectral data.
- Citations
- 1
- FWCI
- 3.95
- Field percentile
- top 10%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- X-ray fluorescence microscopy exposure estimates using a single excitation energy
Benjamin Roter, Andrew M. Crawford, … Chris J. Jacobsen·Journal of Synchrotron RadiationPeer-reviewed·Jun 2, 2026
- Advances on sparse Dynamic Scanning in Spectromicroscopy through Compressive Sensing
G. Kourousias, F. Bille, … A. Gianoncelli·bioRxiv·Apr 14, 2023
- Correlative transmission electron microscopy and high-resolution hard X-ray fluorescence microscopy of cell sections to measure trace elements concentrations at the organelle level
V. Tardillo Suarez, B. Gallet, … A. Deniaud·Journal of Structural BiologyPeer-reviewed·Sep 1, 2021
- MINFLUX fluorescence nanoscopy in biological tissue
Thea Moosmayer, Kamila A. Kiszka, … Stefan W. Hell·Proceedings of the National Academy of SciencesPeer-reviewed·Dec 20, 2024
- Curved Axially Scanned Light-Sheet Microscopy
Steven J. Sheppard, Tatsuya C. Murakami, Douglas P. Shepherd·OpticaPeer-reviewed·Feb 10, 2026
- Scan field rotation with a K-mirror for fast two-photon imaging along curved planes
Shinjini Ghosh, Luca Godenzini, … Peter Rupprecht·bioRxiv·Oct 13, 2026