bioRxivBioengineeringPreprint
A 512-ch dual-mode microchip for simultaneous measurements of electrophysiological and neurochemical activities
Abstract
In the study of the brain, large and high-density microelectrode arrays have been widely used to study the behavior of neurotransmission. CMOS technology has facilitated these devices by enabling the integration of high-performance amplifiers directly on-chip. Usually, these large arrays measure only the voltage spikes resulting from action potentials traveling along firing neuronal cells. However, at synapses, communication between neurons occurs by the release of neurotransmitters, which cannot be measured on typical CMOS electrophysiology devices. Development of electrochemical amplifiers has resulted in the measurement of neurotransmitter exocytosis down to the level of a single vesicle. To effectively monitor the complete picture of neurotransmission, measurement of both action potentials and neurotransmitter activity is needed. Current efforts have not resulted in a device that is capable of the simultaneous measurement of action potential and neurotransmitter release at the same spatiotemporal resolution needed for a comprehensive study of neurotransmission. In this paper, we present a true dual-mode CMOS device that fully integrates 256-ch electrophysiology amplifiers and 256-ch electrochemical amplifiers, along with an on-chip 512 electrode microelectrode array capable of simultaneous measurement from all 512 channels. Electrochemical amplifiers achieve a noise level of 4.51 pARMS with a bandwidth of 10.3 kHz. Electrophysiology amplifiers exhibit 24.9 VRMS noise in the action potential band and a total usable bandwidth from 0.2 Hz to 10 kHz.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Development of a Microelectrode Array System for Simultaneous Measurement of Field Potential and Glutamate Release in Brain Slices
Aiko Hasegawa, Naoki Matsuda, Ikuro Suzuki·Biosensors and BioelectronicsPeer-reviewed·Jun 17, 2025
- A 128-ch area-efficient neurochemical-sensing front-end for FSCV recordings of dopamine
K. A. White, M. Darroudi, … B. N. Kim·bioRxiv·Jun 20, 2023
- Large-area electrical imaging having single neuron resolution using 236,880 electrodes CMOS-MEA technology
Ikuro Suzuki, Naoki Matsuda, … Y. Ishibashi·bioRxiv·Nov 9, 2022
- CHIME: CMOS-hosted in-vivo microelectrodes for massively scalable neuronal recordings
Mihály Köllő, Romeo Rácz, … Andreas T. Schaefer·Frontiers in NeurosciencePeer-reviewed·Aug 11, 2020
- Parallel 1024-ch Cyclic Voltammetry on Monolithic CMOS Electrochemical Detector Array
K. A. White, G. Mulberry, B. N. Kim·bioRxiv·Oct 10, 2019
- Integration of microprism and microelectrode arrays enables simultaneous electrophysiology and two-photon imaging across all cortical layers