Real-time AI integration for MR to detect artifacts and guide pulse sequence adaptations
Aaron T. GudmundsoniD, Zahra ShamsiD, Abdelrahman GadiD, Shuyuan WangiD, Dunja SimičićiD, Saipavitra Murali‐ManohariD, Gizeaddis Lamesgin SimegniD, İpek ÖzdemiriD, Christopher W. Davies‐JenkinsiD, Yulu SongiD, Vivek Srikar YedavalliiD, Georg OeltzschneriD, Ömer Burak DemireliD, Jeremias SulamiD, Michael SchäriD, Sandeep GanjiiD, Richard A.E. EddeniD
Abstract
This work presents a first-of-its-kind artificial intelligence (AI-)integrated MR pulse sequence that detects out-of-voxel (OOV) artifacts in real-time (within-TR) and responds prospectively by updating the crusher gradient scheme. Per Excitation Real-time Execution & Guided Responses with Integrated Neural-network Evaluation (PEREGRINE), allows for deployment of deep learning models and pulse sequence updates. In this study, PEREGRINE operated a time-domain (TD) and frequency-domain (FD) convolutional autoencoder that detect OOV artifacts. Scans without (AI-off) and with (AI-on) updates were collected from the medial prefrontal cortex of healthy volunteers using a MEGA-edited MRS experiment. The degree of OOV contamination (OOV Score) was quantified per transient based upon the prevalence of OOV signals in the TD and FD data. OOV Scores above a user-defined threshold triggered an update of the crusher gradient scheme, iterating through 48 permutations (6 axis transpositions x 8 polarity flips). Within each 2-second TR, PEREGRINE successfully provided single-transient OOV Scores and updated gradients accordingly. No difference was observed between the OOV Scores from the full ('Full' condition) AI-on and AI-off sessions due to the AI-on scan cycling over better and worse gradient permutations relative to the AI-off scan. However, the AI-on scan had significantly lower OOV Scores than the AI-off scan when selecting the transients where PEREGRINE persisted ('Dwell' condition) on a given gradient permutation. Ultimately, Fit Quality Number (FQN) from linear combination modeling improved significantly for the AI-on compared to the AI-off scan. PEREGRINE enabled an adaptive and AI-integrated sequence allowing for real-time evaluation and response to OOV artifacts, identifying gradient modifications that produced less OOV contamination.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mastering Artifact Correction in Neuroimaging Analysis: A Retrospective Approach
Alícia Oliveira, Beatriz Cepa, … Antonio Augusto Soares de Sousa·bioRxiv·Aug 2, 2024
- Application of a 1H Brain MRS Benchmark Dataset to Deep Learning for Out-of-Voxel Artifacts
Aaron T. Gudmundson, Christopher W. Davies‐Jenkins, … Richard A.E. Edden·Imaging NeurosciencePeer-reviewed·Oct 6, 2023
- Deep learning, data ramping, and uncertainty estimation for detecting artifacts in large, imbalanced databases of MRI images
Ricardo Pizarro, Haz-Edine Assemlal, … Amir Shmuel·Medical Image AnalysisPeer-reviewed·Sep 9, 2023
- dStripe: slice artefact correction in diffusion MRI via constrained neural network
Maximilian Pietsch, Daan Christiaens, … Jacques‐Donald Tournier·Medical Image AnalysisPeer-reviewed·Sep 27, 2021
- High-fidelity fast volumetric brain MRI using synergistic wave-controlled aliasing in parallel imaging and a hybrid denoising generative adversarial network
Ziyu Li, Qiyuan Tian, … Susie Y. Huang·Medical PhysicsPeer-reviewed·Dec 28, 2021
- Identifying out-of-voxel echoes in edited MRS with phase cycle inversion
Zahra Shams, Abdelrahman Gad, … Richard A.E. Edden·Magnetic Resonance in MedicinePeer-reviewed·Dec 14, 2025