JNCI Cancer SpectrumCancer BiologyPeer-reviewed journal article
Tumor localization strategies of multi-cancer early detection tests: a quantitative assessment
Christopher TysoniD, Kevin H. Li, Xiting CaoiD, James M. O’BrieniD, Elliot K. FishmaniD, Elizabeth O’DonnelliD, Carlos DuraniD, Vijay M. ParthasarathyiD, Seema P. RegoiD, Omair A. ChoudhryiD, Tomasz M. BeeriD
Abstract
IntroductionBlood-based multi-cancer early detection (MCED) tests may expand the number of "screenable" cancers. Defining an optimal approach to diagnostic resolution for individuals with positive MCED test results is critical. Two prospective trials employed distinct diagnostic resolution approaches; one employed a molecular signal to predict tissue of origin (TOO) and the other used an imaging-based diagnostic strategy. Using mathematical modeling, we compared the diagnostic burden of each approach and characterized the risk of excess cancer incidence that may be attributable to radiation exposure associated with a false positive (FP) MCED test result and an imaging-based diagnostic strategy. MethodsA mathematical expression for diagnostic burden was derived using MCED test positive predictive value (PPV), molecular TOO localization accuracy, and the expected number of imaging procedures associated with each diagnostic outcome. Imaging and molecular TOO strategies were compared by estimating diagnostic burden across a wide range of MCED PPVs and TOO accuracies. Organ-specific radiation dose for diagnostic imaging was extracted from the literature and used as input to National Cancer Institute RADRat tool for estimating excess lifetime cancer risk due to radiation exposure. ResultsFor the molecular TOO diagnostic approach, an average of 2.1 procedures are required to reach diagnostic resolution for correctly-localized TPs, 4.4 procedures for incorrectly-localized TPs, and 4 procedures for FPs, vs. an average of 2.75 procedures for TPs and 2.4 for FPs with an imaging-based diagnostic strategy. Across the entire range of possible PPV and localization performance, a molecular TOO strategy resulted in a higher mean diagnostic burden: 3.6 procedures (SD 0.445) vs. 2.6 procedures (SD 0.1) for the imaging strategy. Predicted diagnostic burden was higher for molecular TOO in 95.5% of all possible PPV and TOO accuracy combinations; 79% or higher PPV would be required for a 90% accurate molecular TOO strategy to be less burdensome than imaging. The maximum rate of excess cancer incidence from radiation exposure for FP results from MCED screening between the ages of 50-84 was estimated at 64.6 per 100,000 (annual testing, 99% specificity), 48.5 per 100,000 (biennial testing, 98.5% specificity), and 64.6 per 100,000 (biennial testing, 98% specificity). ConclusionsThis analysis demonstrates that an imaging-based diagnostic strategy is more efficient than a molecular TOO-informed approach across 95.5% of all possible MCED PPV and TOO accuracy combinations. The use of an imaging-based approach for cancer localization can be efficient and low risk compared to a molecular-based approach.
- Citations
- 7
- FWCI
- 2.86
- Field percentile
- top 9%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Challenges in Using ctDNA to Achieve Early Detection of Cancer
Imran S Haque, Olivier Elemento·bioRxiv·Dec 21, 2017
- A mathematical model of ctDNA shedding predicts tumor detection size
S. Avanzini, D. M. Kurtz, … J. G. Reiter·bioRxiv·Feb 12, 2020
- Single-section multiplexed imaging enables comprehensive lung cancer diagnosis
Raz Ben-Uri, Tal Keidar Haran, … Leeat Keren·bioRxiv·Apr 24, 2026
- Medical diagnostic radiation promotes murine Apc/Kras-driven colon carcinogenesis
Mélissandre Gomot, Nora Essakhi, … Guillaume Varès·bioRxiv·Jun 15, 2026
- Assessment of Circulating Copy Number Variant Detection for Cancer Screening
Bhuvan Molparia, Eshaan Nichani, Ali Torkamani·bioRxiv·Feb 29, 2016
- New High Throughput Approaches to Detect Partial-body and Neutron Exposures on an Individual Basis
I. Shuryak, H. C. Turner, … D. J. Brenner·bioRxiv·May 23, 2019