bioRxivBioengineeringPreprint
Algorithm-Powered Analyzer for Continuous Electrochemistry: A Toolkit for Real-Time Electrochemical Data Analysis
Yan Song JiangiD, Yihang CheniD, Yufei Cai, Keyang Zhou, Hayden J. Ousley, Jun LiiD, Hyongsok Tom SohiD, Kaiyu X. FuiD
- Citations
- 0
Abstract
Real-time biosensors offer significant potential for continuous monitoring of biomolecules. However, their practical application and further development face challenges on data analysis, including poor signal-to-noise ratio when effective sensing area decreases due to signal degradation by biofouling, time-consuming and subjective process of manual or semi-automated peak identification, and inconsistencies in data interpretation, thereby complicating reproducibility and cross-comparison of biosensing results. In this study, we introduce the Algorithm-Powered Analyzer for Continuous Electrochemistry (A-PACE), an open-source toolkit providing streamlined and automated data analysis protocol optimized for real-time electrochemical data analysis. A-PACE comprises three modules: (1) Change point detection for automated identification of peak regions; (2) Baseline fitting with multiple algorithms to handle diverse electrochemical signals and baseline screening to eliminate unreasonable fits; (3) Large dataset input with user-friendly interface for data processing, exporting and visualization. To ensure optimal performance, we curated a training set of 2000 electrochemical curves from an extensive electrochemical dataset (>100,000 curves) collected over the past five years under varied electrochemical measurement conditions. These curves were analyzed using 2046 algorithm sets to identify a default algorithm set, compared to existing tools, demonstrating its capability in peak detection and baseline fitting across a broad spectrum of electrochemical data. Case studies reveal the A-PACE can analyze month-long in vitro serum data and week-long in vivo intravenous blood data, extending the operational lifespan of real-time sensors. This cross-platform compatible toolkit supports both real-time and post-processing analysis, reducing the processing time from minute level per signal by human labeling to second level by A-PACE and subjectivity associated with electrochemical signal processing. By providing this solution for continuous electrochemical data analysis, A-PACE enhances biosensors applications in medical diagnostics and continuous monitoring with high throughput analysis.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Real-time electrochemical protein monitoring using molecular pendulum sensors
Vuslat Buk Juska, Zhiyuan Chen, … Hossein Zargartalebi·bioRxiv·Jul 31, 2026
- Robust Regularization Enables Automated, Real-Time Square-Wave Voltammetry Signal Quantification
Max Yates, Jenny Ji, … Hyongsok Tom Soh·bioRxiv·Jul 27, 2026
- Automated Pipeline for Infants Continuous EEG (APICE): a flexible pipeline for developmental studies
Ana Fló, Giulia Gennari, … Ghislaine Dehaene‐Lambertz·Developmental Cognitive NeurosciencePeer-reviewed·Jan 25, 2022
- An All-In-One Software Solution for Automated Processing of LA-ICP-TOF-MS datasets
Andrew M. Crawford, David Z. Zee, … Keith W. MacRenaris·Journal of Analytical Atomic SpectrometryPeer-reviewed·Jan 1, 2025
- R-DECO: An open-source Matlab based graphical user interface for the detection and correction of R-peaks
J. Moeyersons, M. Amoni, … C. Varon·bioRxiv·Feb 25, 2019
- Machine Learning-Augmented Analysis of Nano-electrochemical Sensor Data for Predictive and Quantitative Assays of Complex Biological Samples
Chaitanya Gupta, Kishan Aryasomayajula, … Emmanuel P. Quévy·bioRxiv·Nov 27, 2025