Author
James Leggett
University of NottinghamORCID 0000-0002-6719-5741Unclaimed ORCID profile · follow to get notified of new preprints
Biology Disciplines
Click to filter author papersSignature Assays, Organisms & Methods
Click to filter · or open tagActivity by Year
2019-2023 · peak 3/yrCo-Author Collaboration Network
10 top collaborators · 45 mutual co-author links7 papers
Recent·Most cited
- NeuroscienceIEEE Transactions on Biomedical EngineeringPeer-reviewed
Magnetic Field Mapping and Correction for Moving OP-MEG
Stephanie Mellor, Tim M. Tierney, George C. O’Neill…·Gareth Robert Barnes
This paper models and corrects magnetic field variations in moving OP-MEG data to reduce movement artefacts.
56 citations - NeuroscienceNeuroImagePeer-reviewed
Measuring functional connectivity with wearable MEG
Elena Boto, Ryan M. Hill, Molly Rea…·Matthew J. Brookes
This study demonstrates that a wearable OPM-MEG system can accurately characterize brain networks, showing high similarity to data from a cryogenic MEG system.
132 citationstop 1% - NeuroscienceScientific ReportsPeer-reviewed
Pragmatic spatial sampling for wearable MEG arrays
Tim M. Tierney, Stephanie Mellor, George C. O’Neill…·Gareth Robert Barnes
This paper investigates the optimal number and placement of sensors in wearable MEG systems, showing that few sensors at coarse sampling can achieve adequate spatial discrimination under high SNR.
48 citations - NeuroscienceNeuroImagePeer-reviewed
Mouth magnetoencephalography: A unique perspective on the human hippocampus
Tim M. Tierney, Andrew D Levy, Daniel N. Barry…·Gareth Robert Barnes
This paper investigates the use of mouth-based sensors in magnetoencephalography (MEG) to study the human hippocampus, finding that mouth sensors show unique task-related activity and anti-correlation with temporal lobe sensors.
87 citationstop 3% - NeuroscienceNeuroImagePeer-reviewed
Multi-Channel Whole-Head OPM-MEG: Helmet Design and a Comparison with a Conventional System
Ryan M. Hill, Elena Boto, Molly Rea…·Matthew J. Brookes
The paper constructs and evaluates a 49-channel whole-head OPM-MEG system, showing comparable performance to cryogenic MEG with a rigid helmet design.
284 citationstop 1% - NeuroscienceThe Journal of PhysiologyPeer-reviewed
Using optically-pumped magnetometers to measure magnetoencephalographic signals in the human cerebellum
Chin‐Hsuan Lin, Tim M. Tierney, Niall Holmes…·R. Chris Miall
This paper demonstrates that optically-pumped magnetometers improve cerebellar MEG signal detection by reducing sensor distance and increasing SNR, revealing evoked and induced responses to sensory stimuli.
63 citations