Donatas SederevičiusiD, Atle BjørnerudiD, Kristine Beate WalhovdiD, Koen Van LeemputiD, Bruce R. FischliD, Anders M. FjelliD
Abstract
Variations in image intensities between magnetic resonance imaging (MRI) acquisitions affect the subsequent image processing and its derived outcomes. Therefore, it is necessary to normalize images of different scanners/acquisitions, especially for longitudinal studies where a change of scanner or pulse sequence often happens. Here, we propose a robust intensity distribution alignment (RIDA) method to remove between-scan effects. The method is based on MRI T1w images acquired in close succession and robustly aligns two cumulative distribution functions (CDF) of voxel intensities to improve image-derived outcomes of a range of subcortical brain structures with different acquisition parameters. We compare RIDA with the other image harmonization methods: mica and RAVEL. We study three intra-scanner and three inter-scanner protocol variations among the same 20 participants scanned with Siemens 1.5T Avanto, 3T Skyra, and 3T Prisma scanners on the same day and use image-derived volumetric outputs from the Sequence Adaptive Multimodal Segmentation (SAMSEG) method. We find that CDF-based intensity harmonization (mica and RIDA) significantly reduces intensity differences, improves consistency in volume quantification, and increases spatial overlap between two images acquired in close succession. The improvements are most considerable if the intensity normalization is based on subcortical structures only (RIDA), excluding cortical regions, instead of the whole brain. However, the effect of the corrections varies considerably as a function of the compared scanners and sequences. In conclusion, the RIDA scaneffect normalization improves the consistency of image-derived measures, but its performance depends on several factors.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Normalization of MRI T1w between-scan effects for improved longitudinal volumetric estimates
Donatas Sederevičius, Atle Bjørnerud, … Anders M. Fjell·bioRxiv·Jun 19, 2022
- Intensity Warping for multisite MRI Harmonization
Julia Wrobel, Melissa L. Martin, … on behalf of the NAIMS Cooperative·NeuroImagePeer-reviewed·Aug 13, 2020
- MISPEL: A supervised deep learning harmonizationmethod for multi-scanner neuroimaging data
Mahbaneh Eshaghzadeh Torbati, Davneet Singh Minhas, … Dana Tudorascu·Medical Image AnalysisPeer-reviewed·Aug 9, 2023
- A resource for development and comparison of multi-modal brain 3T MRI harmonisation approaches
Shaun Warrington, Asante Ntata, … Stamatios N. Sotiropoulos·Imaging NeurosciencePeer-reviewed·Nov 20, 2023
- Toward Large-Scale Preclinical Neuroimaging: Quantifying Inter-Scanner Variability in Mouse Brain MRI
Moussa Shahid, Jiangyang Zhang·bioRxiv·Jun 2, 2026
- MidRISH: Unbiased harmonization of rotationally invariant harmonics of the diffusion signal
Nancy R. Newlin, Michael E. Kim, … Daniel Moyer·Magnetic Resonance ImagingPeer-reviewed·Sep 1, 2024