bioRxivBioengineering
Analysis of physiological noise in quantitative cardiac magnetic resonance
Abstract
PurposeTo determine the impact of imaging parameters on the temporal signal-to-noise ratio (TSNR) of quantitative cardiac magnetic resonance (MR) in humans, and to determine applicability of the physiological noise covariance (PNC) model for physiological noise (PN).\n\nMethodsWe conducted MRI experiments in four healthy volunteers, and obtained series of short-axis cardiac images acquired with snapshot balanced steady-state free precession (bSSFP) and snapshot gradient echo (GRE) using a broad range of spatial resolutions and parallel imaging acceleration factors commonly used in quantitative cardiac MR. We measured regional SNR and TSNR in these datasets and fit the measurements to the PNC model for PN, which assumes that PN scales with signal strength.\n\nResultsThe relationship between SNR and TSNR in human cardiac MR without contrast preparation was well modeled by the PNC model. SNR consistently decreased as the spatial resolution (matrix size) and acceleration factor (R) increased for both GRE and bSSFP imaging. TSNR varied linearly with SNR using GRE imaging, when SNR was low (SNR 40).\n\nConclusionsThe PNC model can be used to guide the choice of matrix size and acceleration factor to optimize TSNR in stable contrast cardiac MR, such as T2-prepared Blood-Oxygen-Level-Dependent (BOLD) and several variants of Arterial Spin Labeled (ASL) cardiac MR.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- 21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)
W. T. Clarke, L. Hingerl, … C. T. Rodgers·bioRxiv·Dec 10, 2021
- Improving the reliability of T2 measurement in magnetic resonance imaging
Xiuli Yang·bioRxiv·Jun 9, 2024
- Temporal signal-to-noise changes in combined multiband- and slice-accelerated echo-planar imaging with a 20- and 64-channel coil
Philipp Seidel, Seth M. Levine, … Jens Volkmar Schwarzbach·Scientific ReportsPeer-reviewed·Mar 26, 2020
- K-space sampling strategies to reduce noise induced by cardiac pulsatility in brain maps of R2* and magnetic susceptibility
Quentin Raynaud, Thomas Dardano, … Antoine Lutti·bioRxiv·Aug 20, 2024
- A characterization of cardiac-induced noise in R2* maps of the brain
Quentin Raynaud, Giulia Di Domenicantonio, … Antoine Lutti·Magnetic Resonance in MedicinePeer-reviewed·Sep 14, 2023
- Physiological noise modeling in fMRI based on the pulsatile component of photoplethysmograph
Michalis Kassinopoulos, Georgios D. Mitsis·NeuroImagePeer-reviewed·Aug 11, 2021