21/2-minute 3D 7T 31P-MRSI of the human heart using concentric rings (CRT)
W. T. Clarke, L. Hingerl, B. Strasser, W. Bogner, L. Valkovic, C. T. Rodgers
Abstract
A 3D density-weighted concentric ring trajectory (CRT) MRSI sequence is implemented for cardiac 31P-MRS at 7T. The point-by-point k-space sampling of traditional phase-encoded CSI sequences severely restricts the minimum scan time at higher spatial resolutions. Our proposed CRT sequence implements a stack of concentric rings trajectory, with a variable number of rings and planes spaced to optimise the density of k-space weighting. This creates flexibility in acquisition time, allowing acquisitions substantially faster than traditional phase-encoded CSI sequences, while retaining high SNR. We first characterise the signal-to-noise ratio and point spread function of the CRT sequence in phantoms. We then evaluate it at five different acquisition times and spatial resolutions in the hearts of five healthy participants at 7T. These different sequence durations are compared with existing published 3D acquisition-weighted CSI sequences with matched acquisition times and spatial resolutions. To minimise the effect of noise on the short acquisitions, low-rank denoising of the spatio-temporal data was also performed after acquisition. The proposed sequence measures 3D localised PCr/ATP ratios of the human myocardium in 2.5 minutes, 2.6 times faster than the minimum scan time for the acquisition-weighted phase-encoded CSI. Alternatively, in the same scan time a 1.7-times smaller nominal voxel volume can be achieved. Low-rank denoising reduced the variance of measured PCr/ATP ratios by 11% across all protocols. The faster acquisitions permitted by 7T CRT 31P-MRSI could make cardiac stress protocols or creatine kinase rate measurements (which involve repeated scans) more tolerable for patients without sacrificing spatial resolution.
02 /Specification & Classification
Click any tag to browse matching papers- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multi-site Ultrashort Echo Time 3D Phosphorous MRSI repeatability using novel Rosette Trajectory (PETALUTE)
Şeyma Alçiçek, Alexander R. Craven, … Uzay E. Emir·bioRxiv·Feb 7, 2024
- K-space sampling strategies to reduce noise induced by cardiac pulsatility in brain maps of R2* and magnetic susceptibility
Quentin Raynaud, Thomas Dardano, … Antoine Lutti·bioRxiv·Aug 20, 2024
- Analysis of physiological noise in quantitative cardiac magnetic resonance
- Density-Weighted Concentric Ring Trajectory using simultaneous multi-band acceleration: 3D Metabolite-cycled Magnetic Resonance Spectroscopy Imaging at 3 T
Pingyu Xia, Mark Chiew, … Uzay E. Emir·bioRxiv·May 5, 2019
- Fast in vivo 23Na imaging and T2* mapping using accelerated 2D-FID magnetic resonance spectroscopic imaging at 3 T: Proof of concept and reliability study
A. A. Alhulail, P. Xia, … U. E. Emir·bioRxiv·May 25, 2020
- In vivo quantification of creatine kinase kinetics in mouse brain using 31P-MRS at 7 Tesla
Mohamed Tachrount, Sean Smart, … Antoine Cherix·bioRxiv·Sep 9, 2024