bioRxivBioengineeringPreprint
Improving the reliability of T2 measurement in magnetic resonance imaging
Abstract
Magnetic resonance imaging (MRI) is a versatile technique broadly utilized in research and clinic. Among the information available from MRI measurements, transversal relaxation time (T2) is a basic but critical one to reflect the microstructure and microenvironment at the molecular level. A popular method to estimate T2 is employing a series of evolution time (TE) values and, thereafter, fitting with the exponential model (termed as T2 fitting). Despite of the popularity in using T2 fitting, there is a lack of knowledge how related experimental parameters, such as signal-to-noise (SNR), number of TE utilized, dynamic range of TE, and repetition number of each TE, affect the measurement reproducibility. In this study, we performed Monte Carlo simulations to investigate how SNR, TE number, TE range, and repetition number influence the reliability of T2 measurement, which was indexed by coefficient of variations. Good reliability with [≤]5.0% variation can be achieved when the normalized noise level is below 2.2%. Optimal TE range for measuring T2 is related to the T2 under evaluation. TE number and repetition number can be increased to reduce measurement variations.
- Citations
- 5
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Time-division multiplexing (TDM) sequence removes bias in T2 estimation and relaxation-diffusion measurements
Qiang Liu, Borjan A. Gagoski, … Lipeng Ning·Magnetic Resonance in MedicinePeer-reviewed·Aug 13, 2024
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T
Jiaen Liu, Peter van Gelderen, … Xiaoping Wu·Magnetic Resonance in MedicinePeer-reviewed·Apr 7, 2026
- The Future is 2D: Spectral-Temporal Fitting of Dynamic Magnetic Resonance Spectroscopy Data Provides Exponential Gains in Precision Over Conventional Approaches
A. Tal·bioRxiv·Jun 23, 2022
- Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study
Catarina Rua, William T. Clarke, … Christopher T. Rodgers·NeuroImagePeer-reviewed·Sep 9, 2020
- Comparison of test-retest reproducibility of DESPOT and 3D-QALAS for water T1 and T2 mapping
Gizeaddis Lamesgin Simegn, Borjan A. Gagoski, … Richard A.E. Edden·bioRxiv·Aug 15, 2024
- Multidimensional T1-T2 Relaxation Imaging In Vivo on a Portable 0.064~T MRI Scanner
Ella Wilczynski, Kulam Najmudeen Magdoom, … Peter J. Basser·bioRxiv·Sep 9, 2026