Network NeuroscienceNeurosciencePeer-reviewed journal article
An Evaluation of the Efficacy of Single-Echo and Multi-Echo fMRI Denoising Strategies
Toby ConstableiD, Jeggan TiegoiD, Kane PavlovichiD, Arshiya SangchooliiD, Priscila Thalenberg LeviiD, Bree Hartshorn, Jessica KweeiD, Kate Fortune, Kate Cooper, Sam Brown, James McLauchlaniD, N. Tran, Rebecca O’NeilliD, Mark A. BellgroveiD, Alex FornitoiD
- Citations
- 2
- FWCI
- 0.00
- Field percentile
- 4th percentile
Abstract
Resting-state functional magnetic resonance imaging (rsfMRI) is commonly used to study brain-wide patterns of inter-regional functional coupling (FC). However, the resulting signals are vulnerable to multiple sources of noise, such as those related to non-neuronal physiological fluctuations and head motion, which can alter FC estimates and influence their associations with behavioral outcomes. The best strategy for acquiring and processing rsfMRI data to mitigate noise remains an open question. In this study of 358 healthy individuals, we compared the denoising efficacy of 60 multi-echo (ME) and 30 single-echo (SE) rsfMRI preprocessing pipelines across six distinct measures of data quality. We also evaluated how each pipeline influences the effect sizes of FC-based predictive models of personality and cognitive measures estimated via cross-validated kernel ridge regression. We found that ME pipelines generally showed superior denoising efficacy to SE pipelines, but that no single pipeline was associated with both superior denoising efficacy and behavioural prediction. Using a heuristic scheme to rank pipelines across benchmark evaluations, we found that an ME acquisition combined with Automatic Removal of Motion Artifacts Independent Component Analysis (ICA-AROMA) and Regressor Interpolation at Progressive Time Delays (RIPTiDe) offered a reasonable compromise between denoising efficacy and brain-behavior predictions for both ME and SE data. In general, ME pipelines ranked more highly than SE pipelines. These findings support the use of ME acquisitions in future work but suggest that no single denoising pipeline should be considered optimal for all purposes.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The efficacy of resting-state fMRI denoising pipelines for motion correction and behavioural prediction.
Kane Pavlovich, James Christopher S. Pang, … Alex Fornito·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- An evaluation of the efficacy, reliability, and sensitivity of motion correction strategies for resting-state functional MRI
Linden Parkes, Ben Fulcher, … Alex Fornito·NeuroImagePeer-reviewed·Dec 24, 2017
- Evaluating the efficacy of multi-echo ICA denoising on model-based fMRI
Adam Steel, Brenda D. Garcia, … Caroline Elizabeth Robertson·NeuroImagePeer-reviewed·Oct 31, 2022
- Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
Abraham B. Beckers, Gerhard S. Drenthen, … Dániel Keszthelyi·NeuroImagePeer-reviewed·Sep 3, 2023
- Eigenvalue Signatures Reveal Residual Motion Effects Across Resting-State fMRI Denoising Strategies
Lejian Huang, Andrew David Vigotsky, A. Vania Apkarian·bioRxiv·Sep 14, 2026
- Pitfalls and recommended strategies and metrics for suppressing motion artifacts in functional MRI
V. Raval, K. P. Nguyen, … A. A. Montillo·bioRxiv·Sep 18, 2021