Evaluating the efficacy of multi-echo ICA denoising on model-based fMRI
Adam SteeliD, Brenda D. GarciaiD, Edward H. SilsoniD, Caroline Elizabeth RobertsoniD
Abstract
fMRI is an indispensable tool for neuroscience investigation, but this technique is limited by multiple sources of physiological and measurement noise. These noise sources are particularly problematic for analysis techniques that require high signal-to-noise ratio for stable model fitting, such as voxel-wise modeling. Multi-echo data acquisition in combination with echo-time dependent ICA denoising (ME-ICA) represents one promising strategy to mitigate physiological and hardware-related noise sources as well as motion-related artifacts. However, most studies employing ME-ICA to date are resting-state fMRI studies, and therefore we have a limited understanding of the impact of ME-ICA on task or model-based fMRI paradigms. Here, we addressed this knowledge gap by comparing data quality and model fitting performance on data acquired during a visual population receptive field (pRF) mapping paradigm (N=13 participants) after using one of three preprocessing procedures: ME-ICA, optimally combined multi-echo data without ICA-denoising, and typical single echo processing. As expected, multi-echo fMRI improved temporal signal-to-noise compared to single echo fMRI, with ME-ICA amplifying the improvement compared to optimal combination alone. However, unexpectedly, this boost in temporal signal-to-noise did not directly translate to improved model fitting performance: compared to single echo acquisition, model fitting was only improved after ICA-denoising. Specifically, compared to single echo acquisition, ME-ICA resulted in improved variance explained by our pRF model throughout the visual system, including anterior regions of the temporal and parietal lobes where SNR is typically low, while optimal combination without ICA did not. ME-ICA also improved reliability of parameter estimates compared to single echo and optimally combined multi-echo data without ICA-denoising. Collectively, these results suggest that ME-ICA is effective for denoising task-based fMRI data for modeling analyses and maintains the integrity of the original data. Therefore, ME-ICA may be beneficial for complex fMRI experiments, including task fMRI studies, voxel-wise modeling, and naturalistic paradigms.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 27
- FWCI
- 2.27
- Field percentile
- top 12%
- Organism
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Impact of multi-echo ICA modeling decisions on motor-task fMRI analysis
Neha Reddy, Michelle C. Medina, … Molly G. Bright·Aperture NeuroPeer-reviewed·Jul 16, 2026
- Denoising task-correlated head motion from motor-task fMRI data with multi-echo ICA
Neha Reddy, Kristina M. Zvolanek, … Molly G. Bright·Imaging NeurosciencePeer-reviewed·Dec 7, 2023
- A comparison of single and multi-echo processing of fMRI data during overt autobiographical recall
Adrian W. Gilmore, Anna M. Agron, … Alex D. Martin·bioRxiv·Nov 3, 2021
- Comparing the efficacy of data-driven denoising methods for a multi-echo fMRI acquisition at 7T
Abraham B. Beckers, Gerhard S. Drenthen, … Dániel Keszthelyi·NeuroImagePeer-reviewed·Sep 3, 2023
- An Evaluation of the Efficacy of Single-Echo and Multi-Echo fMRI Denoising Strategies
Toby Constable, Jeggan Tiego, … Alex Fornito·Network NeurosciencePeer-reviewed·Jan 1, 2026
- Using Temporal ICA to Selectively Remove Global Noise While Preserving Global Signal in Functional MRI Data
Matthew F. Glasser, Timothy S. Coalson, … Stephen M. Smith·NeuroImagePeer-reviewed·Aug 2, 2018