Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study
Catarina RuaiD, William T. ClarkeiD, Ian D. DriveriD, Olivier E. MouginiD, Andrew MorganiD, Stuart ClareiD, Susan FrancisiD, Keith W. MuiriD, Richard G. WiseiD, T. A. Carpenter, Guy B. WilliamsiD, James Benedict RoweiD, Richard W BowtelliD, Christopher T. RodgersiD
Abstract
We present the reliability of ultra-high field T2* MRI at 7T, as part of the UK7T Networks "Travelling Heads" study. T2*-weighted MRI images can be processed to produce quantitative susceptibility maps (QSM) and R2* maps. These reflect iron and myelin concentrations, which are altered in many pathophysiological processes. The relaxation parameters of human brain tissue are such that R2* mapping and QSM show particularly strong gains in contrast-to-noise ratio at ultra-high field (7T) vs clinical field strengths (1.5 - 3T). We aimed to determine the inter-subject and inter-site reproducibility of QSM and R2* mapping at 7T, in readiness for future multi-site clinical studies. MethodsTen healthy volunteers were scanned with harmonised single- and multi-echo T2*-weighted gradient echo pulse sequences. Participants were scanned five times at each "home" site and once at each of four other sites. The five sites had 1x Philips, 2x Siemens Magnetom, and 2x Siemens Terra scanners. QSM and R2* maps were computed with the Multi-Scale Dipole Inversion (MSDI) algorithm (https://github.com/fil-physics/Publication-Code). Results were assessed in relevant subcortical and cortical regions of interest (ROIs) defined manually or by the MNI152 standard space. Results and DiscussionMean susceptibility ({chi}) and R2* values agreed broadly with literature values in all ROIs. The inter-site within-subject standard deviation was 0.001 - 0.005 ppm ({chi}) and 0.0005 - 0.001 ms-1 (R2*). For {chi} this is 2.1-4.8 fold better than 3T reports, and 1.1-3.4 fold better for R2*. The median ICC from within- and cross-site R2* data was 0.98 and 0.91, respectively. Multi-echo QSM had greater variability vs single-echo QSM especially in areas with large B0 inhomogeneity such as the inferior frontal cortex. Across sites, R2* values were more consistent than QSM in subcortical structures due to differences in B0-shimming. On a between-subject level, our measured {chi} and R2* cross-site variance is comparable to within-site variance in the literature, suggesting that it is reasonable to pool data across sites using our harmonised protocol. ConclusionThe harmonized UK7T protocol and pipeline delivers on average a 3-fold improvement in the coefficient of reproducibility for QSM and R2* at 7T compared to previous reports of multi-site reproducibility at 3T. These protocols are ready for use in multi-site clinical studies at 7T.
- Citations
- 50
- FWCI
- 2.31
- Field percentile
- top 10%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- The impact of coregistration of gradient recalled echo images on quantitative susceptibility and R2* mapping at 7T
S. Choi, X. Li, D. Harrison·bioRxiv·Jan 24, 2019
- Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T
Jiaen Liu, Peter van Gelderen, … Xiaoping Wu·Magnetic Resonance in MedicinePeer-reviewed·Apr 7, 2026
- Multi-centre, multi-vendor 7 Tesla fMRI reproducibility of hand digit representation in the human somatosensory cortex
Ian D. Driver, Rosa M Sanchez Panchuelo, … Susan Francis·bioRxiv·Mar 25, 2021
- A geometric anthropomorphic phantom for quantitative susceptibility mapping: accuracy and repeatability
Padriac Hooper, Jin Jin, … Markus Barth·bioRxiv·Sep 2, 2026
- Multi-echo Quantitative Susceptibility Mapping: How to Combine Echoes for Accuracy and Precision at 3 T
Emma Biondetti, Anita Karsa, … Karin Shmueli·Magnetic Resonance in MedicinePeer-reviewed·Jun 29, 2022
- Comparison of test-retest reproducibility of DESPOT and 3D-QALAS for water T1 and T2 mapping
Gizeaddis Lamesgin Simegn, Borjan A. Gagoski, … Richard A.E. Edden·bioRxiv·Aug 15, 2024