Magnetic Resonance in MedicineBioengineeringPeer-reviewed journal article
Mesoscopic whole-brain T2*-weighted and associated quantitative MRI in healthy humans at 10.5 T
Jiaen LiuiD, Peter van GeldereniD, Jacco A. de ZwartiD, Jeff H. DuyniD, Yujia HuangiD, Shuxian QuiD, Andrea GrantiD, Edward J. AuerbachiD, Matt WaksiD, Russell LagoreiD, Lance J. DelaBarreiD, Alireza Sadeghi‐TarakamehiD, Yiğitcan EryamaniD, Gregor AdrianyiD, Kǎmil UǧurbiliD, Xiaoping WuiD
Abstract
PurposeTo demonstrate the feasibility and performance of mesoscopic whole brain T2*-weighted (T2*w) MRI at 10.5 T by combining a motion-robust multi-echo gradient-echo (GRE) method with high-density RF receive arrays. MethodsMulti-echo GRE data were collected in healthy adults at isotropic 0.5 mm resolution using a custom-built 16-channel transmit/80-channel receive (16Tx/80Rx) RF coil. Whole brain images were reconstructed with navigator-guided joint motion and field correction and were used for quantitative R2* and susceptibility ({chi}) mapping. Intrinsic signal-to-noise ratio (iSNR) and quantification precision for R2* and{chi} were also estimated. The results were compared with those obtained in the same subjects with matched resolution at 7 T using the commercial Nova 1Tx/32Rx coil, to demonstrate the iSNR and quantification precision gains at 10.5 T. G-factors were also calculated at each field strength to evaluate parallel imaging performances. To demonstrate the benefit of increased parallel imaging performances at 10.5 T, whole brain images with higher acceleration were also obtained using a custom-built 16Tx/128Rx coil. Resultsthe utilized motion robust GRE sequence and reconstruction effectively reduced artifacts from motion and field changes during scans, producing high-quality whole-brain T2*w images and multi-parametric maps at 10.5 T with delineation of fine-scale brain structures. Compared to 7 T, the 10.5 T approach led to gains in both iSNR and quantification precision of R2* and{chi} . Quantitatively, iSNR estimated in the peripheral cortical gray matter increased by 42%. Parallel imaging performances were also improved at 10.5 T owing to the utilized high-density coils compared to the commonly used commercially available coil at 7 T, allowing high-quality images with up to 12-fold combined acceleration when using the 128Rx coil. ConclusionIt is feasible to perform motion-robust whole-brain mesoscopic multi-echo gradient echo imaging of the human brain at 10.5 T. Intrinsic SNR and quantification precision of R2* and{chi} were estimated and compared with 7 T results. The results presented here may shed light on future optimal implementation of anatomic T2*w brain MRI at ultrahigh field beyond 7 T.
- Citations
- 1
- FWCI
- 0.00
- Field percentile
- 25th percentile
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Mesoscopic in vivo human T2* dataset acquired using quantitative MRI at 7 Tesla
Ömer Faruk Gülban, Saskia Bollmann, … Dimo Ivanov·NeuroImagePeer-reviewed·Nov 11, 2022
- Multi-centre, multi-vendor reproducibility of 7T QSM and R2* in the human brain: results from the UK7T study
Catarina Rua, William T. Clarke, … Christopher T. Rodgers·NeuroImagePeer-reviewed·Sep 9, 2020
- Spanning spatial scales with functional imaging in the human brain; initial experiences at 10.5 Tesla
Luca Vizioli, Lasse Knudsen, … Kǎmil Uǧurbil·bioRxiv·Dec 20, 2024
- The Taco Setup: A Novel TMS-fMRI Setup for High Resolution Whole Brain Imaging
Moataz Assem, Marius Mada, … Alexandra Woolgar·bioRxiv·Jun 14, 2025
- Multidimensional T1-T2 Relaxation Imaging In Vivo on a Portable 0.064~T MRI Scanner
Ella Wilczynski, Kulam Najmudeen Magdoom, … Peter J. Basser·bioRxiv·Sep 9, 2026
- A 128-channel receive array with enhanced SNR performance for 10.5 tesla brain imaging
Russell Lagore, Alireza Sadeghi‐Tarakameh, … Kǎmil Uǧurbil·bioRxiv·Oct 20, 2024