bioRxivNeurosciencePreprint
DACO: Distortion/artefact correction for diffusion MRI data in an integrated framework
Abstract
In this paper we propose a registration-based algorithm to correct various distortions or artefacts (DACO) commonly observed in diffusion weighted (DW) magnetic resonance images (MRI). The registration in DACO is proceeded on the basis of a pseudo b0 image, which is synthesized from the anatomical images such as T1-weighted image or T2-weighted image, and a pseudo diffusion MRI (dMRI) data, which is derived from the Gaussian model of diffusion tensor imaging (DTI) or the Hermite model of MAP-MRI. DACO corrects (1) the susceptibility-induced distortions, (2) the intensity inhomogeneity, and (3) the misalignment between the dMRI data and anatomical images by registering the real b0 image to the pseudo b0 image, and corrects (4) the eddy current (EC)-induced distortions and (5) the head motions by registering each of the DW images in the real dMRI data to the corresponding image in the pseudo dMRI data. As the above artefacts interact with each other, DACO models each type of artefact in an integrated framework and estimates these models in an interleaved and iterative manner. The mathematical formulation of the models and the comprehensive estimation procedures are detailed in this paper. The evaluation using the human connectome project data shows that DACO could estimate the model parameters accurately. Furthermore, the evaluation conducted on the real human data acquired from clinical MRI scanners reveals that the method could reduce the artefacts effectively. The DACO method leverages the anatomical image, which is routinely acquired in clinical practice, to correct the artefacts, minimizing the additional acquisitions needed to conduct the algorithm. Therefore, our method is beneficial to most dMRI data, particularly to those without acquiring the field map or blip-up and blip-down images.
- Citations
- 1
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Distortion correction of diffusion weighted MRI without reverse phase-encoding scans or field-maps
K. G. Schilling, J. Blaber, … B. A. Landman·bioRxiv·Jan 19, 2020
- Diffusion MRI Head Motion Correction Methods are Highly Accurate but Impacted by Denoising and Sampling Scheme
Matthew Cieslak, Philip A. Cook, … Theodore Daniel Satterthwaite·Human Brain MappingPeer-reviewed·Jan 30, 2024
- Surface-driven registration method for the structure-informed segmentation of diffusion MR images
Oscar Esteban, Dominique Zosso, … Andres Santos·bioRxiv·Feb 3, 2016
- Evaluation of six phase encoding based susceptibility distortion correction methods for diffusion MRI
Xuan Gu, Anders Eklund·Frontiers in NeuroinformaticsPeer-reviewed·Dec 5, 2019
- Eddy current-induced artifacts correction in high gradient strength diffusion MRI with dynamic field monitoring: demonstration in ex vivo human brain imaging
G. Ramos Llorden, D. Park, … S. Y. Huang·bioRxiv·Feb 15, 2023
- NOise Reduction with DIstribution Corrected (NORDIC) PCA in dMRI with complex-valued parameter-free locally low-rank processing
Steen Moeller, Pramod Kumar Pisharady, … Mehmet Akçakaya·NeuroImagePeer-reviewed·Nov 10, 2020