bioRxivPhysiology
Bi-level positive airway pressure (biPAP) for non-invasive respiratory support of foals
S. L. Raidal, L. L. Burgemeestre, C. S. M. Catanchin, C. T. Quinn
Abstract
Respiratory insufficiency and pulmonary health are important considerations in equine neonatal care, as the majority of foals are bred for athletic function. The administration of supplementary oxygen is readily implemented in equine practice settings, but this does not address respiratory insufficiency due to inadequate ventilation and is no longer considered optimal care for hypoxia in some settings. Non-invasive ventilatory strategies including continuous or bi-level positive airway pressure are effective in human and veterinary studies, and may offer improved respiratory support in equine clinical practice. The current study was conducted in two parts to investigate the use of a commercial bilevel positive airway pressure (biPAP) ventilator, designed for home care of people with obstructive respiratory conditions, for respiratory support of foals. In Part 1 a prospective observational study was conducted to evaluate the effect of sequential application of supplementary oxygen and then biPAP for respiratory support of five foals [≤] 4 days of age hospitalised with respiratory in sufficiency (Group 1) and four healthy, sedated foals < 28 days of age (Group 2). In Part 2, biPAP and supplementary oxygen were administered to six healthy foals with pharmacologically induced respiratory insufficiency in a two sequence, two phase, cross-over study (Group 3). Non-invasive ventilation by biPAP improved gas exchange and mechanics of breathing (increased tidal volume, decreased respiratory rate and increased peak inspiratory flow) in foals, but modest hypercapnia was observed in healthy, sedated foals (Groups 2 and 3). Clinical cases (Group 1) appeared less likely to develop hypercapnia in response to treatment, however the response in individual foals was variable, and close monitoring is necessary. Clinical observations, pulse oximetry and CO2 monitoring of expired gases were of limited benefit in identification of foals responding inappropriately to biPAP, and improved methods to assess and monitor respiratory function are required in foals.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Evaluating The Efficacy Of Endotracheal Epinephrine Administration At Standard Versus High Dose During Resuscitation Of Severely Asphyxiated Newborn Lambs: A Randomized Preclinical Study
G. R. Polglase, Y. Brian, … C. Roberts·bioRxiv·Feb 28, 2023
- Effects of sustained inflation pressure during neonatal cardiopulmonary resuscitation of asphyxiated piglets
G.-H. Shim, S. Y. Kim, … G. M. Schmölzer·PLOS ONEPeer-reviewed·Jun 23, 2020
- Aeration Strategy at Birth Does Not Impact Carotid Blood Flow and Oxygen Delivery in Preterm Lambs
- Acute buprenorphine exposure depresses neonatal respiratory chemoreflexes in the presence or absence of naloxone
Michael L. Frazure, Khushi Praveen, … Ralph Frank Fregosi·bioRxiv·May 17, 2026
- A Pumpless Microfluidic Neonatal Lung Assist Device for Support of Preterm Neonates in Respiratory Distress
M. Dabaghi, N. Rochow, … P. R. Selvaganapathy·bioRxiv·Feb 22, 2020
- Endogenous responses in brain pH and PO2 in a rodent model of birth asphyxia
Alexey S. Pospelov, Martin Puskarjov, … Juha Voipio·Acta PhysiologicaPeer-reviewed·Mar 16, 2020