Biomarker-Aware Super-Resolution for 4D Flow MRI in a Synthetic Pulmonary-Artery Benchmark

Aitor Zubillaga-UnsainiD, Adrian Lluveras-SiresiD, César Caballero‐GaudesiD, Jesús Ruı́z-CabelloiD

Abstract

Purpose: To evaluate, within a synthetic pulmonary-artery benchmark, whether biomarker-aware super-resolution improves hemodynamic endpoint fidelity in 4D flow MRI. Methods: A 3D residual channel attention network (RCAN) was trained on 22 CFD simulations from 11 pulmonary-artery geometries with 2x spatial degradation. The original primary comparison evaluated full biomarker-aware training against a combined divergence-temporal-regularization control across 14 matched seeds on a fixed six-case test set. Additional matched analyses subsequently separated divergence and adjacent-frame temporal-difference regularization and evaluated biomarker supervision in a controlled 2x2 design with a common reconstruction schedule. Results: In the original primary comparison, biomarker-aware training reduced PI error relative to the matched combined-regularization control (12.76 +/- 2.34% vs. 17.12 +/- 1.23%; paired difference -4.35 percentage points [95% CI -5.58, -3.09]; p = 0.0015). In the matched factorial analysis, biomarker supervision reduced PI error without (-2.235 percentage points [95% CI -3.514, -0.849]) and with (-4.125 percentage points [95% CI -5.392, -2.732]) combined regularization. PI improvement was not mirrored by uniformly improved reconstruction metrics: PSNR changed by -0.058 (p = 0.50) and +0.144 dB (p = 0.28), while SSIM decreased by 0.009 (p = 0.004) and 0.007 (p = 0.009), respectively. Divergence alone changed PI by +0.034 percentage points [95% CI -0.705, 0.809] while reducing DivRMS by 1.869 percentage points; temporal-difference regularization increased PI error by 1.562 percentage points [95% CI 0.594, 2.439]. Conclusion: Within this synthetic, fixed-case RCAN benchmark, biomarker supervision improved PI under both regularization conditions. PI improvement was not mirrored by uniformly improved reconstruction metrics. Temporal-difference - not divergence - regularization was the only isolated component associated with reproducible PI deterioration. These findings are configuration-specific and require geometry-independent and in vivo validation.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.

Similarity Map
SelectedSame fieldCross-field
THISZubillaga-U '26Ferdian '21Maidu '24Demirel '23Tunedal '25Adame‐Gonza '26
66% semantic matchBioengineering