Imaging NeuroscienceNeurosciencePeer-reviewed journal article
Leveraging Multi-Echo EPI to Enhance BOLD Sensitivity in Task-based Olfactory fMRI
Ludwig Sichen ZhaoiD, Clara U. RaitheliD, Matthew Dylan TisdalliD, John A. DetreiD, Jay A. GottfriediD
Abstract
Functional magnetic resonance imaging (fMRI) using blood-oxygenation-level-dependent (BOLD) contrast relies on gradient echo echo-planar imaging (GE-EPI) to quantify dynamic susceptibility changes associated with the hemodynamic response to neural activity. However, acquiring BOLD fMRI in human olfactory regions is particularly challenging due to their proximity to the sinuses where large susceptibility gradients induce magnetic field distortions. BOLD fMRI of the human olfactory system is further complicated by respiratory artifacts that are highly correlated with event onsets in olfactory tasks. Multi-echo EPI (ME-EPI) acquires gradient echo data at multiple echo times (TEs) during a single acquisition and can leverage signal evolution over the multiple echo times to enhance BOLD sensitivity and reduce artifactual signal contributions. In the current study, we developed a ME-EPI acquisition protocol for olfactory task-based fMRI and demonstrated significant improvement in BOLD signal sensitivity over conventional single-echo EPI (1E-EPI). The observed improvement arose from both an increase in BOLD signal changes through a T2*-weighted echo combination and a reduction in non-BOLD artifacts through the application of the Multi-Echo Independent Components Analysis (ME-ICA) denoising method. This study represents one of the first direct comparisons between 1E-EPI and ME-EPI in high-susceptibility regions and provides compelling evidence in favor of using ME-EPI for future task-based fMRI studies.
- Citations
- 6
- FWCI
- 1.53
- Field percentile
- top 19%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Comparing the effect of multi gradient echo and multi band fMRI during a semantic task
Ajay D. Halai, Richard N. Henson, … Marta Correia·Imaging NeurosciencePeer-reviewed·Jan 1, 2025
- The effects of multi-echo fMRI combination and rapid T2*-mapping on offline and real-time BOLD sensitivity
Stephan Heunis, Marcel M. Breeuwer, … Albert Pierre Aldenkamp·NeuroImagePeer-reviewed·Jun 8, 2021
- Mapping Whole-Brain Auditory Activation with 3T Multi-Echo fMRI at the Group and Individual-Subject Level
Michelle C. Medina, Neha A. Reddy, … Molly G. Bright·Hearing ResearchPeer-reviewed·Mar 21, 2026
- Asymmetric spin echo multi-echo echo planar imaging (ASEME-EPI) sequence for pre-clinical high-field fMRI
Kyle A. Johnson, Christopher P. Pawela, … Jason W. Sidabras·bioRxiv·Oct 12, 2024
- Simultaneous pure T2 and varying T2'-weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·NeuroImagePeer-reviewed·Oct 14, 2021
- Optimising 7T-fMRI for imaging regions of magnetic susceptibility
Saskia L Frisby, Marta Correia, … Ajay D. Halai·Human Brain MappingPeer-reviewed·Aug 1, 2026