Improving laser standards for three-photon microscopy
Abstract
SignificanceThree-photon excitation microscopy has double-to-triple the penetration depth in biological tissue over two-photon imaging and thus has the potential to revolutionize the visualization of biological processes in vivo. However, unlike the plug-and-play operation and performance of lasers used in two-photon imaging, three-photon microscopy presents new technological challenges that require a closer look at the fidelity of laser pulses. AimWe implemented state-of-the-art pulse measurements and developed new techniques for examining the performance of lasers used in three-photon microscopy. We then demonstrated how these techniques can be used to provide precise measurements of pulse shape, pulse energy and pulse-to-pulse intensity variability, all of which ultimately impact imaging. ApproachWe built inexpensive tools, e.g., a second harmonic generation frequency resolved optical gating (SHG-FROG) device, and a deep-memory diode imaging (DMDI) apparatus, to examine laser pulse fidelity. ResultsFirst, SHG-FROG revealed very large third order dispersion (TOD). This extent of phase distortion prevents the efficient temporal compression of laser pulses to their theoretical limit. Furthermore, TOD cannot be quantified when using a conventional method of obtaining the laser pulse duration, e.g., when using an autocorrelator. Finally, DMDI showed the effectiveness of detecting pulse-to-pulse intensity fluctuations on timescales relevant to three-photon imaging, which were otherwise not captured using conventional instruments and statistics. ConclusionsThe distortion of individual laser pulses caused by TOD poses significant challenges to three-photon imaging by preventing effective compression of laser pulses and decreasing the efficiency of nonlinear excitation. Moreover, an acceptably low pulse-to-pulse amplitude variability should not be assumed. Particularly for low repetition rate laser sources used in three-photon microscopy, pulse-to-pulse variability also degrades image quality. If three-photon imaging is to become mainstream, our diagnostics may be used by laser manufacturers to improve system design and by end-users to validate the performance of their current and future imaging systems.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- In situ pulse dispersion estimation via third-harmonic generation interferometric autocorrelation for multiphoton microscopy
Liam Shaughnessy, Lauren Vannell, … Cristina Rodríguez·bioRxiv·Oct 28, 2026
- Three-photon light-sheet fluorescence microscopy
A. Escobet-Montalban, F. M. Gasparoli, … K. Dholakia·bioRxiv·Aug 17, 2018
- Video-rate three-photon imaging in deep Drosophila brain based on a single Cr:forsterite oscillator
L.-T. Chou, S.-H. Wu, … S.-H. Chia·bioRxiv·Mar 23, 2023
- Dual-plane 3-photon microscopy with remote focusing
Kevin Takasaki, Dmitri A. Tsyboulski, Jack Waters·Biomedical Optics ExpressPeer-reviewed·Oct 8, 2019
- Characterization of red fluorescent reporters for dual-color in vivo three-photon microscopy
Michael Andrew Thornton, Gregory L. Futia, … Ethan G. Hughes·NeurophotonicsPeer-reviewed·Apr 28, 2022
- Cellular-resolution Three-photon Ultra-Deep Imaging (TrUDI) of neuronalpopulation activity at 2 mm depth in the mammalian brain
Kalyan Santra, Kevin Barber¹, … Alipasha Vaziri·Nature MethodsPeer-reviewed·Oct 28, 2026