Validation of Fuze IMU system for ergonomics assessments
Abstract
This study aims to validate the Fuze system (SwiftMotion, CA, USA), against the gold standard for motion capture, a 3D infra-red motion capture system (Vicon Nexus, Oxford, UK). Fuze system uses inertial measurement units and proprietary algorithms to calculate position and orientation of each body segment Six subjects (3M and 3F) performed two activities that simulate common occupational physical activities. For both systems, we calculated the following joint angles: trunk relative to horizontal, left and right shoulder and hip joint angles. We also calculated the horizontal distance of each wrist relative to the the fifth lumbar vertebra. For each measurement, we calculated Bias (average difference between Fuze and Vicon system) and root mean squared error (RMSE). We also compared each measurement using a Statistical Parametric Mapping (SPM) method with a statistical significance level set at 0.05. Compared to Vicon, Fuze system had a maximum Bias of 5.63 {+/-} 1.60 degrees for the left shoulder angle and a maximum RMSE of 10.03 {+/-} 2.73 degrees for the left hip angle. SPM analysis evidenced that for all the measurements, comparisons were within the critical thresholds for significance for the whole duration of the trials, indicating that we could not find a significant difference between Vicon and Fuze measurements. In conclusion: the Fuze system compares well with the Vicon system and provides reliable data for the measurement of joint angles and body positions, that can be used in particular in non labbased settings, for example in ergonomics risk assessments.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- IMU-based upper limb kinematics validation: sensor fusion optimisation, sensor-to-segment alignment, and joint angle accuracy.
Arthur Fabre, Graham Kerr, … Wolbert van den Hoorn·bioRxiv·Sep 30, 2026
- Romiumeter: An Open-Source Inertial Measurement Unit-Based Goniometer for Range of Motion Measurements
Basinepalli Kothireddy Gari Diwakarreddy, S Abishek, … Sivakumar Balasubramanian·bioRxiv·May 29, 2024
- Validity and sensitivity of an inertial measurement unit-driven biomechanical model of motor variability for gait
- Validation of two-dimensional video-based inference of finger kinematics with pose estimation
L. Gionfrida, W. Rusli, … A. E. Kedgley·bioRxiv·Jun 22, 2022
- OpenSense: An open-source toolbox for Inertial-Measurement-Unit-based measurement of lower extremity kinematics over long durations
M. Al Borno, J. O'Day, … S. Delp·Journal of NeuroEngineering and RehabilitationPeer-reviewed·Feb 20, 2022
- Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis