High-SNR Whole-Brain Mesoscale Diffusion MRI Using Rotating-View Acquisitions (ROVER-dMRI)
Qiang Liu, Yunqi WangiD, Yiang Pan, Xingwang YongiD, YuTing CheniD, Hwihun Jeong, Nan Wang, Erpeng DaiiD, Jarrett RushmoreiD, Carl‐Fredrik WestiniD, Lauren J. O’DonnelliD, Berkin BilgiçiD, Kawin SetsompopiD, Deniz Erdogmus BiD, Lipeng NingiD, Yogesh Rathi AiD
Abstract
Purpose: We aim to acquire and reconstruct high signal-to-noise ratio (SNR), whole-brain, mesoscale (isotropic submillimeter) diffusion MRI (dMRI) in vivo in a clinically feasible scan time. Methods: We present ROVER-dMRI, a unified rotating-view acquisition and super-resolution reconstruction framework. Thick slices (up to 10 mm)acquired across many rotated orientations improve the base SNR, and a shared multi-resolution hash-encoded implicit neural representation (INR) with per-direction MLP head and a physics-informed, Bloch-simulated slice-profile forward model reconstructs these views into a continuous isotropic volume (up to 13x super-resolution) in a self-supervised manner. ROVER-dMRI was evaluated in vivo on human brain (0.78 mm isotropic and 0.5 mm isotropic) and monkey brain (0.6 mm isotropic) across MRI platforms with varying gradient performance, and benchmarked against gSlider-SMS and least-squares super-resolution reconstruction (LS-SRR). Results: At 0.78 mm isotropic resolution, ROVER-dMRI diffusion- weighted images achieved higher SNR than the vendor product sequence, whose images were limited by the noise floor, while its directionally encoded color (DEC) maps showed lower noise than gSlider. When reducing the number of views from 20 to 13 (reducing the scan time by 65% ), ROVER-dMRI acquisition/reconstruction preserved all fine details in the fiber orientations. In the monkey brain, its DEC map matched a 60-direction gSlider acquisition at only 40% of the scan time. ROVER-dMRI preserved coherent fiber-orientation-distribution (FOD) structure, including crossing fibers, and recovered fine details in the cerebellum at 0.5 mm isotropic, that are not visible at 0.78 mm resolution. Compared to state-of- the-art 0.5 mm methods, ROVER-dMRI reduced scan time by 73% while acquiring more diffusion directions. Conclusion: ROVER-dMRI offers a practical route to high-SNR whole-brain mesoscale diffusion imaging in vivo, with the pulse sequence and reconstruction pipeline released as open source. KEYWORDS: diffusion MRI, super-resolution, implicit neural representation, hash encoding, physics informed learning
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution
Geraline Vis, Markus Nilsson, … Filip Szczepankiewicz·NeuroImagePeer-reviewed·Oct 21, 2021
- In vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolution
Fuyixue Wang, Zijing Dong, … Kawin Setsompop·Scientific DataPeer-reviewed·Apr 29, 2021
- Submillimeter diffusion MRI using an in-plane segmented 3D multi-slab acquisition and denoiser-regularized reconstruction
Ziyu Li, Silei Zhu, … Wenchuan Wu·Medical Image AnalysisPeer-reviewed·Oct 10, 2025
- Super-resolution mapping of anisotropic tissue structure with diffusion MRI and deep learning
David Abramian, Anders Eklund, Evren Özarslan·bioRxiv·Apr 4, 2023
- Increased Sensitivity and Signal-to-Noise Ratio in Diffusion-Weighted MRI using Multi-Echo Acquisitions
Cornelius Eichner, Michael Paquette, … Alfred Anwander·NeuroImagePeer-reviewed·Jul 15, 2020
- FONDUE: Robust resolution-invariant denoising of MR Images using Nested UNets
Walter Adame‐Gonzalez, Aliza Brzezinski-Rittner, … Mahsa Dadar·Imaging NeurosciencePeer-reviewed·Jan 1, 2024