bioRxivBioengineering
Plantarflexor Moment Arms Estimated From Tendon Excursion In Vivo Are Not Well Correlated With Geometric Measurements
Abstract
Geometric and tendon excursion methods have both been used extensively for estimating plantarflexor muscle moment arm in vivo. Geometric measures often utilize magnetic resonance imaging, which can be costly and impractical for many investigations. Estimating moment arm from tendon excursion measured with ultrasonography may provide a cost-effective alternative to geometric measures of moment arm, but how well such measures represent geometry-based moment arms remains in question. The purpose of this study was to determine whether moment arms from tendon excursion can serve as a surrogate for moment arms measured geometrically. Magnetic resonance and ultrasound imaging were performed on 19 young male subjects to quantify plantarflexor moment arm based on geometric and tendon excursion paradigms, respectively. These measurements were only moderately correlated (R2 = 0.21, p = 0.052), and moment arm from tendon excursion under-approximated geometric moment arm by nearly 40% (p 0.05). Our results suggest that the moment arms from musculoskeletal geometry cannot be otherwise obtained by simply scaling moment arms estimated from tendon excursion.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Muscle Moment Arm-Joint Angle Relations in the Hip, Knee, and Ankle: A Visualization of Datasets
Ziyu Chen, David W. Franklin·Annals of Biomedical EngineeringPeer-reviewed·May 9, 2025
- Tendon slack length is the primary determinant of plantarflexor muscle-tendon function in computational simulations of gait
J. R. Baxter, M. W. Hast·bioRxiv·May 22, 2018
- Triceps surae torque-length relationships relevant for walking activity levels with and without an ankle exoskeleton
A. L. Hessel, B. J. Raiteri, … D. Hahn·bioRxiv·Sep 23, 2019
- Novel instrumented insole algorithm accurately approximates plantar flexor loading
T. J. Hullfish, J. R. Baxter·bioRxiv·Dec 20, 2019
- Functional and Structural Moment Arm Validation for Musculoskeletal Models: A Study of the Human Forearm and Hand
Matthew T. Boots, Russell L. Hardesty, … Sergiy Yakovenko·bioRxiv·May 29, 2020
- Sagittal Subtalar and Talocrural Joint Assessment Between Barefoot and Shod Walking: A Fluoroscopic Study
B. D. McHenry, K. M. Kruger, … G. F. Harris·bioRxiv·Jul 27, 2018