Machine learning nominal max oxygen consumption from wearable reflective pulse oximetry with density functional theory
Abstract
Wearable sensors have revolutionized modern health towards precision medicine. Many measurements taken by wearables are not currently used for medical purposes, and their physical roots are not understood. Here we show the origin of inferring oxygen saturation from measuring estimated oxygen variation while preparing for a marathon via spectrophotometric pulsatile blood flow transcutaneous reflectance oximetry, building six years of data tracking the stages of running a marathon. Based on inputs from quantum mechanical simulations into classical wave and electromagnetic theory models, the imaginary part of the complex dielectric function of the active site of human hemoglobin is altered upon oxygen binding to the heme group, changing the extinction coefficient and selectively absorbing wavelengths of light in a way that enables its detection from the ratio of red to infrared absorbance. A fundamental nominal max oxygen consumption is inferred from quantum mechanical absorbance spectra with and without oxygen binding by training a machine learning model on 1.5 years of daily wearable reflective pulse oximetry data with an R2 of 0.84. Reflectance oximetry is strongly correlated (R2 of 0.96) to standard pulse oximetry, such as through earlobe or fingertip, enabling accurate, rapid, regular, and automated monitoring of vital signs with wearable sensors on smart watches and fitness trackers, and supplying artificial intelligence inferences of function-symptom relationships for precision medicine.
02 /Specification & Classification
Click any tag to browse matching papers- Citations
- 0
- Organism
- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Deep spectral learning for label-free optical imaging oximetry with uncertainty quantification
- Spectral emission profile and wavelength tolerances affect pulse oximeter performance
Maximilian F. Reiser, Andreas Breidenassel, Oliver Amft·bioRxiv·Apr 22, 2026
- The effects of skin tone on photoacoustic imaging and oximetry
T. R. Else, L. Hacker, … S. Bohndiek·bioRxiv·Aug 17, 2023
- Estimating intra-subject and inter-subject oxygen consumption in outdoor human gait using multiple neural network approaches
Philipp Müller, Khoa Pham-Dinh, … Neil J. Cronin·PLoS ONEPeer-reviewed·Sep 27, 2024
- Dissolved oxygen minimally affects magnetic susceptibility in biologically relevant conditions
V. Fortier, I. R. Levesque·bioRxiv·Mar 13, 2021
- A Machine Learning Approach to Predicting Dyspnea with Noninvasive Biomarkers
Karapet G. Mkrtchyan, Anser Qazi, … Erica C. Heinrich·Respiratory Physiology & NeurobiologyPeer-reviewed·Apr 12, 2026