Three-dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array
Z. Dong, J. Kim, C. Huang, M. R. Lowerison, S. Chen, P. Song
Abstract
ObjectiveTo develop a 3D shear wave elastography (SWE) technique using a 2D row column addressing (RCA) array, with either external vibration or acoustic radiation force (ARF) as the shear wave source. Impact StatementThe proposed method paves the way for clinical translation of 3D-SWE based on the 2D RCA, providing a low-cost and high volume-rate solution that is compatible with existing clinical systems. IntroductionSWE is an established ultrasound imaging modality that provides a direct and quantitative assessment of tissue stiffness, which is significant for a wide range of clinical applications including cancer and liver fibrosis. SWE requires high frame-rate imaging for robust shear wave tracking. Due to the technical challenges associated with high volume-rate imaging in 3D, current SWE techniques are typically confined to 2D. Advancing SWE from 2D to 3D is significant because of the heterogeneous nature of tissue, which demands 3D imaging for accurate and comprehensive evaluation. MethodsA 3D SWE method using a 2D RCA array was developed with a volume-rate up to 2000 Hz. The performance of the proposed method was systematically evaluated on tissue-mimicking elasticity phantoms. Results3D shear wave motion induced by either external vibration or ARF was successfully detected with the proposed method. Robust 3D shear wave speed maps were reconstructed for both homogeneous and heterogeneous phantoms with inclusions. ConclusionThe high volume-rate 3D imaging provided by the 2D RCA array provides a robust and practical solution for 3D SWE with a clear pathway for future clinical translation.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Three-dimensional Shear Wave Elastography Using Acoustic Radiation Force and A 2-D Row-Column Addressing (RCA) Array
- High Volume Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors
Z. Dong, S. Li, … P. Song·IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency ControlPeer-reviewed·Aug 1, 2023
- In vivo real-time elastography with unmodified commercial endoscopes using noise-correlation-inspired method and laser speckle imaging
Maud Legrand, Nina Dufour, … Amir Nahas·bioRxiv·Jun 29, 2026
- Three-dimensional tissue strain measurement using a row-column array during biaxial testing of excised ventricular myocardium
Xavier Navy, Zhiyu Sheng, … John M. Cormack·Ultrasound in Medicine & BiologyPeer-reviewed·Jun 12, 2025
- Measurements of acoustic radiation force of ultrahigh frequency ultrasonic transducers using model-based approach
- Axial Stress Provides a Lower Bound on Shear Wave Velocity in Active and Passive Muscle
M. Bernabei, S. S. M. Lee, … T. G. Sandercock·bioRxiv·Dec 4, 2021