Abstract
Acoustic radiation force (ARF)-based shear wave elastography (SWE) is a clinically available ultrasound imaging mode that noninvasively and quantitatively measures tissue stiffness. Current implementations of ARF-SWE are largely limited to 2-D imaging, which does not provide robust estimation of heterogeneous tissue mechanical properties. Existing 3-D ARF-SWE solutions that are clinically available are based on wobbler probes, which cannot provide true 3-D shear wave motion detection. Although 3-D ARF-SWE based on 2-D matrix arrays have been previously demonstrated, they do not provide a practical solution because of the need for a high channel-count ultrasound system (e.g., 1024-channel) to provide adequate volume rates and the delicate circuitries (e.g., multiplexers) that are vulnerable to the long-duration "push" pulses. To address these issues, here we propose a new 3-D ARF-SWE method based on the 2-D row-column addressing (RCA) array which has a much lower element count (e.g., 256), provides an ultrafast imaging volume rate (e.g., 2000 Hz), and can withstand the push pulses. In this study, we combined the comb-push shear elastography (CUSE) technique with 2-D RCA for enhanced SWE imaging field-of-view. In vitro phantom studies demonstrated that the proposed method had robust 3-D SWE performance in both homogenous and inclusion phantoms. An in vivo study on a breast cancer patient showed that the proposed method could reconstruct 3-D elasticity maps of the breast lesion, which was validated using a commercial ultrasound scanner. These results demonstrate strong potential for the proposed method to provide a viable and practical solution for clinical 3-D ARF-SWE.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Three-dimensional Shear Wave Elastography Using a 2D Row Column Addressing (RCA) Array
- High Volume Rate 3-D Ultrasound Imaging Using Fast-Tilting and Redirecting Reflectors
Z. Dong, S. Li, … P. Song·IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency ControlPeer-reviewed·Aug 1, 2023
- Focused acoustic-radiation-force microscopy for live-cell selective nucleus deformation and nucleus viscoelasticity measurement
Natsumi Fujiwara, Hiroki Okita, … Hirotsugu Ogi·bioRxiv·Oct 23, 2025
- Measurements of acoustic radiation force of ultrahigh frequency ultrasonic transducers using model-based approach
- In vivo real-time elastography with unmodified commercial endoscopes using noise-correlation-inspired method and laser speckle imaging
Maud Legrand, Nina Dufour, … Amir Nahas·bioRxiv·Jun 29, 2026
- VESTA: Machine Learning-Enabled Estimation of ViscoElastic Ratios from On-Axis Spatio-Temporal ARFI Features
Simina Mannan Trisha, Md Ashiqur Rahman, … Md Murad Hossain·bioRxiv·Jul 7, 2026