bioRxivBioengineeringPreprint
Biomechanics Characterization of Autonomic and Somatic Nerves by High Dynamic Closed-Loop MEMS force sensing
M. A. Gonzalez-Gonzalez, H. Alemansour, M. Maroufi, M. B. Coskun, D. Lloyd, S. O. R. Moheimani, M. I. Romero-Ortega
Abstract
The biomechanics of peripheral nerves are determined by the blood-nerve barrier (BNB), together with the epineural barrier, extracellular matrix, and axonal composition, which maintain structural and functional stability. These elements are often ignored in the fabrication of penetrating devices, and the implant process is traumatic due to the mechanical distress, compromising the function of neuroprosthesis for sensory-motor restoration in amputees. Miniaturization of penetrating interfaces offers the unique opportunity of decoding individual nerve fibers associated to specific functions, however, a main issue for their implant is the lack of high-precision standardization of insertion forces. Current automatized electromechanical force sensors are available; however, their sensitivity and range amplitude are limited (i.e. mN), and have been tested only in-vitro. We previously developed a high-precision bi-directional micro-electromechanical force sensor, with a closed-loop mechanism (MEMS-CLFS), that while measuring with high-precision (-211.7N to 211.5N with a resolution of 4.74nN), can be used in alive animal. Our technology has an on-chip electrothermal displacement sensor with a shuttle beam displacement amplification mechanism, for large range and high-frequency resolution (dynamic range of 92.9 dB), which eliminates the adverse effect of flexural nonlinearity measurements, observed with other systems, and reduces the mechanical impact on delicate biological tissue. In this work, we use the MEMS-CLFS for in-vivo bidirectional measurement of biomechanics in somatic and autonomic nerves. Furthermore we define the mechanical implications of irrigation and collagen VI in the BNB, which is different for both autonomic and somatic nerves ([~] 8.5-8.6 fold density of collagen VI and vasculature CD31+ in the VN vs ScN). This study allowed us to create a mathematical approach to predict insertion forces. Our data highlights the necessity of nerve-customization forces to prevent injury when implanting interfaces, and describes a high precision MEMS technology and mathematical model for their measurements.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Printable microscale interfaces for long-term peripheral nerve mapping and precision control
Timothy M. Otchy, Christos Michas, … Timothy J. Gardner·Nature CommunicationsPeer-reviewed·Aug 21, 2020
- Ultraconformable cuff implants for long-term bidirectional interfacing of peripheral nerves at sub-nerve resolutions
Alejandro Carnicer‐Lombarte, Alexander J. Boys, … George G. Malliaras·Nature CommunicationsPeer-reviewed·Aug 30, 2024
- A mechanically stable neural probe for percutaneous high-resolution, multichannel recordings in peripheral nerves
Sofiia Demchenko, Erkan Yilmaz, … Viviana Rincón Montes·bioRxiv·Apr 14, 2026
- Ultra-flexible and Stretchable Intrafascicular Peripheral Nerve Recording Device with Axon-dimension, Cuff-less Microneedle Electrode Array
Dongxiao Yan, Ahmad A. Jiman, … John P. Seymour·SmallPeer-reviewed·May 1, 2022
- Mechanical characterization of compliant neural probes, their insertion regimes and a rule of thumb design
Zac Smith·bioRxiv·Sep 18, 2019
- Soft and stretchable organic bioelectronics for continuous intra-operative neurophysiological monitoring during microsurgery