Magnetic Resonance Materials in Physics Biology and MedicineNeurosciencePeer-reviewed journal article
Towards harmonized spectral quantification in MRSI: Comparative analysis of Backward-Linear-Predicted and original 1H-FID-MRSI dephased data
Alessio SivigliaiD, Brayan Alves, Cristina CudalbuiD, Bernard LanziD
- Citations
- 3
- FWCI
- 9.55
- Field percentile
- top 4%
Abstract
ObjectWe hypothesized that the inherent acquisition delay (AD) in {superscript 1}H-FID-MRSI can introduce systematic LCModel quantification biases due to strong spectral dephasing, and that Backward-Linear-Prediction (BLP) reconstruction toward AD = 0 ms can harmonize metabolite estimates across acquisitions with various delays. Materials and Methods2D {superscript 1}H-FID-MRSI were acquired in rats at 14.1T with three AD values (0.71, 0.94, 1.30 ms). Hippocampal metabolites were quantified using LCModel and AD-matched basis sets. Complementary Monte-Carlo simulations (n = 1000) replicated {superscript 1}H-FID-MRSI spectra at multiple ADs under realistic SNR conditions. BLP was applied to in vivo and simulated FIDs to back-predict missing points up to AD = 0 ms, enabling quantification within a unified basis set framework. ResultsIn vivo and simulated data showed clear AD-dependent variations for several metabolites (Gln, tCho, tNAA, Ins, Tau), with discrepancies frequently >10% despite AD-specific basis sets. Simulations confirmed metabolite-specific biases increasing with AD. BLP reconstruction preserved quantification consistency up to [~]0.98 ms of recovered FIDs, reducing inter-AD mismatches in vivo--particularly for Tau, tNAA and tCho--lowering the mean discrepancy from 10.5% to [~]5%. DiscussionThese findings show that AD affects {superscript 1}H-FID-MRSI quantification in LCModel, whereas BLP reconstruction can harmonize spectra across delays by enabling a virtual AD = 0 ms quantification scheme. This supports BLP as a practical strategy to improve consistency and comparability in MRSI studies.
- organism: rat
- assay: multiome
- research focus: benchmarking
- approach: statistical model
- approach: simulation
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Test-retest reproducibility of human brain multi-slice 1H FID-MRSI data at 9.4 T after optimization of lipid regularization, macromolecular model and spline baseline stiffness
Theresia Ziegs, Andrew Martin Wright, A Henning·bioRxiv·Feb 2, 2022
- Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. Bhogal, Tommy A.A. Broeders, … Jannie P. Wijnen·Brain and BehaviorPeer-reviewed·Nov 20, 2020
- Impacts of retrospective lipid suppression on metabolite quantification in preclinical proton MR spectroscopic imaging
Phan Tan Toi, Brayan Alves, … Cristina Cudalbu·bioRxiv·Sep 21, 2026
- Adaptive Baseline Fitting for 1H MR Spectroscopy Analysis
M. Wilson·bioRxiv·Feb 17, 2020
- MRSIPrep: A Standardized Post-Quantification Framework for Preprocessing Whole-Brain Magnetic Resonance Spectroscopic Imaging
Federico Lucchetti, Edgar Céléreau, … Paul Klauser·bioRxiv·Sep 16, 2026
- Whole-Brain High-Resolution Metabolite Mapping with 3D Compressed-Sensing-SENSE-LowRank 1H FID-MRSI
Antoine Klauser, Paul Klauser, … François Lazeyras·NMR in BiomedicinePeer-reviewed·Oct 1, 2021