Adaptive Baseline Fitting for 1H MR Spectroscopy Analysis
Abstract
PurposeAccurate baseline modeling is essential for reliable MRS analysis and interpretation -- particularly at short echo-times, where enhanced metabolite information coincides with elevated baseline interference. The degree of baseline smoothness is a key analysis parameter for metabolite estimation, and in this study a new method is presented to estimate its optimal value. MethodsAn adaptive baseline fitting algorithm (ABfit) is described, incorporating a spline basis into a frequency-domain analysis model, with a penalty parameter to enforce baseline smoothness. A series of candidate analyses are performed over a range of smoothness penalties, as part of a four stage algorithm, and the Akaike information criterion is used to estimate the appropriate penalty. ABfit is applied to a set of simulated spectra with differing baseline features and experimentally acquired 2D MRSI -- both at a field strength of 3 Tesla. ResultsSimulated analyses demonstrate metabolite errors result from two main sources: bias from an inflexible baseline (underfitting) and increased variance from an overly flexible baseline (over-fitting). In the case of an ideal flat baseline ABfit is shown to correctly estimate a highly rigid baseline, and for more realistic spectra a reasonable compromise between bias and variance is found. Analysis of experimentally acquired data demonstrates good agreement with known correlations between metabolite ratios and the contributing volumes of gray and white matter tissue. ConclusionABfit has been shown to perform accurate baseline estimation and is suitable for fully-automated routine MRS analysis.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Research Focus
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Chemical shift and relaxation regularisation improve the accuracy of 1H MR spectroscopy analysis
Martin Wilson·bioRxiv·Jan 6, 2025
- A data-driven algorithm to determine 1H-MRS basis set composition
Christopher W. Davies‐Jenkins, Helge J. Zöllner, … Georg Oeltzschner·Magnetic Resonance in MedicinePeer-reviewed·Aug 16, 2025
- FSL-MRS: An end-to-end spectroscopy analysis package
William T. Clarke, Charlotte Jane Stagg, Saâd Jbabdi·Magnetic Resonance in MedicinePeer-reviewed·Dec 6, 2020
- The Impact of BOLD Induced Linewidth Modulation on Functional 1H MRS Analysis
Martin Wilson, Simon M. Finney, William T. Clarke·NMR in BiomedicinePeer-reviewed·Sep 20, 2026
- Towards harmonized spectral quantification in MRSI: Comparative analysis of Backward-Linear-Predicted and original 1H-FID-MRSI dephased data
Alessio Siviglia, Brayan Alves, … Bernard Lanz·Magnetic Resonance Materials in Physics Biology and MedicinePeer-reviewed·May 14, 2026
- MRSCloud: a Cloud-based MR Spectroscopy Tool for Basis Set Simulation
S. C. N. Hui, M. Saleh, … R. Edden·bioRxiv·Mar 22, 2022