Rapid simultaneous acquisition of macromolecular tissue volume, susceptibility, and relaxometry maps
F. F. Yu, S. Y. Huang, A. Kumar, T. Witzel, C. Liao, T. Duval, J. Cohen-Adad, B. Bilgic
Abstract
PurposeA major obstacle to the clinical implementation of quantitative MR is the lengthy acquisition time required to derive multi-contrast parametric maps. We sought to reduce the acquisition time for quantitative susceptibility mapping (QSM) and macromolecular tissue volume (MTV) by acquiring both contrasts simultaneously by leveraging their redundancies. The Joint Virtual Coil concept with generalized autocalibrating partially parallel acquisitions (JVC-GRAPPA) was applied to reduce acquisition time further. MethodsThree adult volunteers were imaged on a 3T scanner using a multi-echo 3D GRE sequence acquired at three head orientations. MTV, QSM, R2*, T1, and proton density maps were reconstructed. The same sequence (GRAPPA R=4) was performed in subject #1 with a single head orientation for comparison. Fully sampled data was acquired in subject #2, from which retrospective undersampling was performed (R=6 GRAPPA and R=9 JVC-GRAPPA). Prospective undersampling was performed in subject #3 (R=6 GRAPPA and R=9 JVC-GRAPPA) using gradient blips to shift k-space sampling in later echoes. ResultsSubject #1s multi-orientation and single-orientation MTV maps were not significantly different based on RMSE. For subject #2, the retrospectively undersampled JVC-GRAPPA and GRAPPA generated similar results as fully sampled data. This approach was validated with the prospectively undersampled images in subject #3. Using QSM, R2*, and MTV, the contributions of myelin and iron content to susceptibility was estimated. ConclusionWe have developed a novel strategy to simultaneously acquire data for the reconstruction of five intrinsically co-registered 1-mm isotropic resolution multi-parametric maps, with a scan time of 6 minutes using JVC-GRAPPA.
02 /Specification & Classification
Click any tag to browse matching papersReproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Multi-echo Quantitative Susceptibility Mapping: How to Combine Echoes for Accuracy and Precision at 3 T
Emma Biondetti, Anita Karsa, … Karin Shmueli·Magnetic Resonance in MedicinePeer-reviewed·Jun 29, 2022
- A qMRI approach for mapping microscopic water populations and tissue relaxivity in the in vivo human brain.
Shir Filo, Lee Cohen, … Aviv Mezer·bioRxiv·Aug 9, 2024
- Quantification of water exchange across the blood-brain barrier using non-contrast MR fingerprinting
Emma L. Thomson, Elizabeth Powell, … Geoff J.M. Parker·Magnetic Resonance in MedicinePeer-reviewed·May 9, 2024
- 3D Echo Planar Time-resolved Imaging (3D-EPTI) for ultrafast multi-parametric quantitative MRI
F. Wang, Z. Dong, … K. Setsompop·bioRxiv·May 6, 2021
- Multidimensional T1-T2 Relaxation Imaging In Vivo on a Portable 0.064~T MRI Scanner
Ella Wilczynski, Kulam Najmudeen Magdoom, … Peter J. Basser·bioRxiv·Sep 9, 2026
- Investigating the Effect of Flow Compensation and Quantitative Susceptibility Mapping Method on the Accuracy of Venous Susceptibility Measurement
Ronja Berg, Christine Preibisch, … Emma Biondetti·NeuroImagePeer-reviewed·Jul 14, 2021