Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T
Abstract
PurposeTo develop a prospective motion correction (MC) method for phase contrast (PC) MRI of penetrating arteries (PA) in centrum semiovale at 7 T and evaluate its performance using automatic PA segmentation. MethodsHead motion was monitored and corrected during the scan based on fat navigator images. Two convolutional neural networks (CNN) were developed to automatically segment PAs and exclude surface vessels. Real-life scans with MC and without MC (NoMC) were performed to evaluate the MC performance. Motion score was calculated from the range of translational and rotational motion parameters. MC vs NoMC pairs were divided according to their score differences into groups with similar, less, or more motions during MC. Data reacquisition was also performed to evaluate whether it can further improve PA visualization. ResultsIn the group with similar motion, more PA counts (NPA) were obtained with MC in 9 (60%) cases, significantly more than the number of cases (1) with less PAs (p = 0.011; binomial test). In the group with less motion during MC, MC images had more or similar NPA in all cases, while in the group with more motion during MC, the numbers of cases with less and more NPA during MC were not significantly different (3 vs 0). Data reacquisition did not further increase NPA. CNNs had higher sensitivity (0.85) and accuracy (Dice coefficient 0.85) of detecting PAs than a threshold based method. ConclusionsProspective MC and CNN based segmentation improved the visualization and delineation of PAs in PC MRI at 7 T.
02 /Specification & Classification
Click any tag to browse matching papers- Assay
- Approach
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Effects of Prospective Motion Correction on Perivascular Spaces at 7T MRI Evaluated Using Motion Artifact Simulation
Bingbing Zhao, Yichen Zhou, Xiaopeng Zong·Magnetic Resonance in MedicinePeer-reviewed·Apr 23, 2024
- Velocity and Diameter Measurements of Penetrating Arteries by Model Based Analysis of Complex Difference Images in Phase Contrast MRI
Xiaopeng Zong, Weili Lin·bioRxiv·Apr 2, 2018
- Cerebral artery segmentation based on magnetization-prepared two rapid acquisition gradient echo multi-contrast images in 7 Tesla magnetic resonance imaging
Uk-Su Choi, Hirokazu Kawaguchi, Ikuhiro Kida·NeuroImagePeer-reviewed·Aug 13, 2020
- MR-PET head motion correction based on co-registration of multi-contrast MR images
Zhaolin Chen, Francesco Sforazzini, … Gary F. Egan·Human Brain MappingPeer-reviewed·Jan 3, 2019
- Motion correction with subspace-based self-navigation for combined angiography, perfusion and structural imaging
Qijia Shen, Wenchuan Wu, … Thomas W. Okell·bioRxiv·Aug 26, 2024
- Prospective Motion correction improves the sensitivity of fMRI pattern decoding
Pei Huang, Johan D. Carlin, … Marta Correia·Human Brain MappingPeer-reviewed·Jun 8, 2018