bioRxivBioengineering
Effects of Prospective Motion Correction on Perivascular Spaces at 7T MRI Evaluated Using Motion Artifact Simulation
Abstract
PurposeProspective motion correction (PMC) is a promising method in mitigating motion artifacts in MRI. However, its effectiveness in improving the visibility of vessel-like thin structures in routine studies is unclear. In this study, we aim to demonstrate the ability of fat-navigator based PMC in improving the visibility of perivascular spaces (PVS) using data from two earlier studies. MethodsTwo open source MRI data set were used for motion artifact simulation and evaluating PMC, which consist of 66 T2-weighted images without PMC and 38 T2-weighted images with PMC. PMC was performed by adjusting field of view during scan based on motion parameters derived from fat navigators. Motion artifact simulation was performed by misplacing k-space data at a motion-related non-cartesian grid onto the cartesian grid calculated using motion-free images to generate the images without effects of PMC. The simulations ability to reproduce motion-induced blurring and ringing artifacts was evaluated using the sharpness at the lateral ventricle/white matter (WM) boundary and the magnitude of ringing artifact component in the Fourier spectrum. PVS volume fraction in WM was employed to reflect its visibility. Sharpness, magnitude of ringing artifact and PVS volume fraction were then compared between simulated images and real images with and without PMC. ResultsThe consistencies in sharpness (rho [≥] 0.86, corrected p [≤] 4.4 x10-16) and ringing artifact magnitude (rho [≥] 0.42, corrected p [≤] 0.001) were found between simulated images and real images without PMC. There was a significant negative correlation (rho [≤] -0.27, corrected p [≤] 0.08) between PVS volume fraction and motion severity in both simulated and real images without PMC. PMC removed the above correlations (rho [≥] -0.02, corrected p > 1) and increased the boundary sharpness compared to the images simulated using the same motion traces. ConclusionsMotion artifact simulation can reproduce the desired motion-induced artifacts on images. PMC reduces the negative impacts of motion on image quality and improves PVS visibility.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Prospective Motion Correction and Automatic Segmentation of Penetrating Arteries in Phase Contrast MRI at 7 T
J. Moore, J. Jimenez, … X. Zong·bioRxiv·Jan 20, 2022
- Prospective Motion correction improves the sensitivity of fMRI pattern decoding
Pei Huang, Johan D. Carlin, … Marta Correia·Human Brain MappingPeer-reviewed·Jun 8, 2018
- Image processing approaches to enhance perivascular space visibility and quantification using MRI
Farshid Sepehrband, Giuseppe Barisano, … Arthur W. Toga·Scientific ReportsPeer-reviewed·Aug 26, 2019
- Motion correction with subspace-based self-navigation for combined angiography, perfusion and structural imaging
Qijia Shen, Wenchuan Wu, … Thomas W. Okell·bioRxiv·Aug 26, 2024
- MR-PET head motion correction based on co-registration of multi-contrast MR images
Zhaolin Chen, Francesco Sforazzini, … Gary F. Egan·Human Brain MappingPeer-reviewed·Jan 3, 2019
- Velocity and Diameter Measurements of Penetrating Arteries by Model Based Analysis of Complex Difference Images in Phase Contrast MRI
Xiaopeng Zong, Weili Lin·bioRxiv·Apr 2, 2018