Magnetic Resonance in MedicineNeurosciencePeer-reviewed journal article
SNR-Efficient Whole-Brain Pseudo-Continuous Arterial Spin Labeling Perfusion Imaging at 7 Tesla
Joseph G. WoodsiD, Yang JiiD, Hongwei LiiD, Aaron T. HessiD, Thomas W. OkelliD
Abstract
PurposeTo optimize pseudo-continuous arterial spin labeling (PCASL) parameters to maximize SNR efficiency for RF power constrained whole brain perfusion imaging at 7 T. MethodsWe used Bloch simulations of pulsatile laminar flow to optimize the PCASL parameters for maximum SNR efficiency, balancing labeling efficiency and total RF power. The optimization included adjusting the inter-RF pulse spacing (TRPCASL), mean B1+ (B1 ave), slice-selective gradient amplitude (Gmax), and mean gradient amplitude (Gave). In vivo data were acquired from four volunteers at 7 T to validate the optimized parameters. Dynamic B0-shimming and flip angle adjustments were utilized to avoid needing to make the PCASL parameters robust to B0/B1+ variations. ResultsThe optimized PCASL parameters achieved a significant (3.1x) reduction in RF power while maintaining high labeling efficiency. This allowed for longer label durations and minimized deadtime, and resulted in a 126% improvement in SNR efficiency in vivo compared to a previously proposed protocol. Additionally, the static tissue response was improved, reducing the required distance between labeling plane and imaging volume. ConclusionThese optimized PCASL parameters provide a robust and efficient approach for whole brain perfusion imaging at 7 T, with significant improvements in SNR efficiency and reduced SAR burden.
- Citations
- 3
- FWCI
- 1.72
- Field percentile
- top 18%
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Dynamic B0 field shimming for improving pseudo-continuous arterial spin labeling at 7 Tesla
Yang Ji, Joseph G. Woods, … Thomas W. Okell·Magnetic Resonance in MedicinePeer-reviewed·Dec 6, 2024
- Bidirectional crusher gradient method for estimating the labeling efficiency of pseudo-continuous arterial spin labeling MRI in mice
Xiuli Yang, Yuguo Li, … Zhiliang Wei·Magnetic Resonance in MedicinePeer-reviewed·Sep 17, 2025
- Feasibility of high-resolution perfusion imaging using Arterial Spin Labelling MRI at 3 Tesla
Sriranga Kashyap, Icaro Agenor Ferreira de Oliveira, Kâmil Uludaǧ·Frontiers in PhysiologyPeer-reviewed·Jan 3, 2024
- High-resolution perfusion imaging in rodents using pCASL at 9.4 T
Sara Pires Monteiro, Lydiane Hirschler, … Noam Shemesh·NMR in BiomedicinePeer-reviewed·Nov 7, 2024
- Designing and Comparing Optimised Pseudo-Continuous Arterial Spin Labelling Protocols for Measurement of Cerebral Blood Flow
Joseph G. Woods, Michael A. Chappell, Thomas W. Okell·NeuroImagePeer-reviewed·Aug 24, 2020
- Hyperintense signals in cerebral blood flow maps acquired with pseudo-continuous arterial spin labeling MRI in mice
Xiuli Yang, Yuguo Li, … Zhiliang Wei·bioRxiv·Dec 5, 2025