Biomechanical Compatibility With Physiological Limb-Flexion Deformation Reduces Inflammation and Neointimal Hyperplasia After Peripheral Stenting
Alexey V. KamenskiyiD, Barbara Batista de Oliveira, Anastasia S. DesyatovaiD, Frazer I. HeinisiD, Jordan RosenbohmiD, Paul T. Deegan, Pranav S. RenavikariD, Jason MacTaggartiD
Abstract
Introduction: The femoropopliteal artery undergoes substantial axial compression, bending, torsion, and pinching during limb flexion. When an implanted stent does not accommodate these deformations, repetitive biomechanical mismatch may alter the vascular response to implantation and contribute to restenosis. We tested whether designing a peripheral stent to better accommodate physiologic limb-flexion deformation reduces the subsequent inflammatory and neointimal response. Methods: A nitinol stent was developed using multi-objective computational optimization to maintain arterial apposition while reducing wall stress and luminal pinching during physiologic deformation. Sixteen Yucatan minipigs were studied in independent 3- and 6-month cohorts (n=8 each). Each animal received the optimized stent in one limb and a commercial stent with representative biomechanical behavior contralaterally. CTA quantified in vivo limb-flexion deformation, while CT and histology assessed stenosis, neointimal accumulation, inflammatory-cell burden, SMA-positive tissue, and extracellular-matrix composition. Results: The optimized stent accommodated greater axial shortening than the commercial comparator at both 3 months (11.2{+/-}2.7% vs. 6.6{+/-}2.1%, p=0.003) and 6 months (13.7{+/-}4.4% vs. 6.8{+/-}2.3%, p=0.004). Intimal hyperplasia volume was lower with the optimized stent at 3 months (227.5{+/-}85.2 vs. 350.0{+/-}130.5 mm3, p=0.002) and 6 months (183.6{+/-}46.2 vs. 261.2{+/-}60.6 mm3, p=0.001), with significantly lower maximum, mean, and median stenosis at both timepoints. At 3 months, macrophage and total inflammatory-cell counts were 51% and 45% lower, respectively, with the optimized stent. Histologic tissue area was 28% lower at 3 months and 12% lower at 6 months. SMA-positive tissue fraction was higher with the optimized stent at both timepoints, whereas elastin, glycosaminoglycan, and collagen fractions were similar between devices. Discussion: Improved accommodation of limb-flexion deformation was associated with a smaller inflammatory and neointimal response to stent implantation through 6 months, while overall neointimal matrix composition remained largely unchanged. These findings provide in vivo evidence that biomechanical compatibility with the dynamic lower-limb environment can influence vascular healing and should be considered a mechanistic design criterion for peripheral artery stents.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- NITINOL MATERIAL PROPERTIES OF 11 COMMERCIAL PERIPHERAL STENTS DETERMINED USING INVERSE COMPUTATIONAL ANALYSIS
Eric D. Anttila, Kaspars Maleckis, … Alexey V. Kamenskiy·bioRxiv·Nov 27, 2025
- Cell-cultured PDMS vascular model to allow placement of implant devices
Taku Okuno, Kazuyo Ito, … Daisuke Yoshino·BMC MethodsPeer-reviewed·May 11, 2026
- Development of a novel murine model of in-stent neoatherosclerosis
Jiandi Liu, Demeke Geremew, … Christina A. Bursill·Journal of the American Heart AssociationPeer-reviewed·Nov 12, 2025
- Comparing the Effect of Helical-centerline Stent Placement on Blood Flow Velocity with a Straight Stent
- Biomechanical stress, inflammatory change and atheromatous plaque detachment: the role of pulse pressure, arterial wall stiffness and vessel bending. An in-vitro experimental study with some clinical implications
Thomas K Day, Ellie Newman·Cardiology & Vascular ResearchPeer-reviewed·Jul 17, 2025
- Modulation of Arterial Intima Stiffness by Disturbed Blood Flow
G. Rivera, B. Bywaters, A. Trache·bioRxiv·Sep 7, 2023