Abstract

Purpose: To evaluate the performance and usability of a commercially available non-woven fabric electrode as a cost-effective and user-friendly alternative to standard corneal contact lens electrodes for recording murine electroretinograms. Methods: Using a paired design, full-field electroretinograms were recorded in the same mice using the commercially available non-woven fabric electrode and a conventional contact lens electrode. Key parameters evaluated included (1) stability of baseline noise, (2) dark-adapted intensity-response curves (0.01-100 cd{middle dot}s{middle dot}m-2), (3) light-adapted intensity-response curves (3-100 cd{middle dot}s{middle dot}m-2), (4) 20-Hz and 30-Hz flicker responses, (5) extended recordings targeting slow c-wave kinetics under dark-adapted conditions, and (6) inter-eye consistency via bilateral simultaneous recordings. Results: Eliminating the need for viscous lubricants, the non-woven fabric electrode simplified placement on the cornea, alignment, and re-application. It yielded a-wave and b-wave amplitudes and peak times comparable or superior to those obtained with standard contact lens electrodes. Notably, during prolonged recordings, the non-woven fabric electrode yielded significantly larger c-wave amplitudes while maintaining equivalent baseline noise stability. Bilateral simultaneous recordings demonstrated high inter-eye correlation and low variability of measurements between contralateral eyes. Conclusions: The non-woven fabric electrode provides high-quality, reproducible electroretinographic recordings comparable to (and for c-waves superior to) those obtained using standard corneal contact lens electrodes. This method facilitates standardized data acquisition and improves inter-laboratory reproducibility of murine electroretinography. Translational Relevance: By reducing financial and technical barriers, this non-woven fabric electrode offers an alternative to specialized recording setups, improving experimental throughput and efficiency in ophthalmic research.

PDFDOI

02 /Specification & Classification

Click any tag to browse matching papers

Reproducibility ledger

Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.

Sign in to file a reproducibility report.