bioRxivBioengineeringPreprint
Design and Analysis of a Whole Body Non-Contact Electromagnetic Stimulation Device with Field Modulation
Sergey N. Makarov, Gene Bogdanov, Gregory M. NoetscheriD, William Appleyard, Reinhold LudwigiD, Juho Joutsa, Zhi-De Deng
Abstract
This study describes a whole-body, non-contact electromagnetic stimulation device based on the concept of a conventional MRI Radio Frequency (RF) resonating coil, but at a much lower resonant frequency (100-150 kHz), with a field modulation option (0.5-100 Hz) and with an input power of up to 3 kW. Its unique features include a high electric field level within the biological tissue due to the resonance effect and a low power dissipation level, or a low Specific Absorption Rate (SAR), in the body itself. Because of its large resonator volume together with non-contact coupling, the subject may be located anywhere within the coil over a longer period at moderate and safe electric field levels. The electric field effect does not depend on body position within the resonator. However, field penetration is deep anywhere within the body, including the extremities where muscles, bones, and peripheral tissues are mostly affected. A potential clinical application of this device is treatment of chronic pain. Substantial attention is paid to device safety; this includes both AC power safety and exposure of human subjects to electromagnetic fields. In the former case, we employ inductive coupling which eliminates a direct current path from AC power to the coil. Our design enhances overall device safety at any power level, even when operated under higher-power conditions. Human exposure to electromagnetic fields within the coil is evaluated by performing modeling with two independent numerical methods and with an anatomically realistic multi-tissue human phantom. We show that SAR levels within the body correspond to International Electrotechnical Commission (IEC) safety standards when the input power level of the amplifier driver does not exceed 3 kW. We also show that electric field levels generally comply with International Commission on Non-Ionizing Radiation Protection safety standards if the input power level does not exceed 1.5 kW.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Effect of field strength on RF power deposition near conductive leads: A simulation study of SAR in DBS lead models during MRI at 1.5 T - 10.5 T
E. Kazemivalipour, A. Sadeghi-Tarakameh, … L. G. Rad·bioRxiv·Dec 13, 2022
- MRI Powered and Triggered Current Stimulator for Concurrent Stimulation and MRI
R. Mandal, N. B. Babaria, … Z. Liu·bioRxiv·Jul 26, 2019
- Development and assessment of a new multichannel electrocutaneous device for non-invasive somatosensory stimulation for magnetic resonance applications
Carolina Travassos, Alexandre Sayal, … Miguel S. Castelo-Branco·IEEE Transactions on Neural Systems and Rehabilitation EngineeringPeer-reviewed·Jan 1, 2025
- Ultra-high-efficacy Wireless Neuromodulation Using a Conductive Ring Interface
Jieyuan Tian, Shawnus Chen, … Sakhrat Khizroev·bioRxiv·Oct 20, 2026
- Magnetoelectric materials for miniature, wireless neural stimulation at therapeutic frequencies
A. Singer, S. Dutta, … J. T. Robinson·bioRxiv·Mar 15, 2020
- Brain-implanted conductors amplify radiofrequency fields in rodents: advantages and risks
Mihály Vöröslakos, Omid Yaghmazadeh, … György Buzsáki·BioelectromagneticsPeer-reviewed·Oct 24, 2023