bioRxivNeurosciencePreprint
High-Resolution Metabolic Mapping of the Cerebellum Using a Reduced Field of View (Zoomed) Magnetic Resonance Spectroscopic Imaging
Uzay E. EmiriD, Jaiyta Sood, Mark ChiewiD, Albert Thomas, Sean P. LaneiD
Abstract
PurposeThe human cerebellum plays an important role in functional activity cerebrum which is ranging from motor to cognitive activities since due to its relaying role between spinal cord and cerebrum. The cerebellum poses many challenges to magnetic resonance spectroscopic imaging (MRSI) due to the caudal location, the susceptibility to physiological artifacts and partial volume artifact due to its complex anatomical structure. Thus, in present study, we propose a high-resolution MRSI acquisition scheme for the cerebellum. MethodsA zoomed or reduced-field of view (rFOV) metabolite-cycled full-intensity magnetic resonance spectroscopic imaging (MRSI) at 3T with a nominal resolution of 62.5 L was developed. Single-slice rFOV MRSI data were acquired from the cerebellum of 5 healthy subjects with a nominal resolution of 2.5{square}x{square}2.5{square}mm2 in 9{square}minutes 36. Spectra were quantified with LCModel. A spatially unbiased atlas template of the cerebellum was used for analyzing metabolite distributions in the cerebellum. ResultsThe high quality of the achieved spectra enabled to generate a high-resolution metabolic map of total N-acetylaspartate, total creatine, total choline, glutamate+glutamine and myo-inositol with Cramer-Rao lower bounds below 50%. A spatially unbiased atlas template of the cerebellum-based region of interest (ROIs) analysis resulted in spatially dependent metabolite distributions in 9 ROIs. The group-averaging across subjects in the Montreal Neurological Institute-152 template space allowed to generate a very high-resolution metabolite maps in the cerebellum. ConclusionThese findings indicate that very high-resolution metabolite probing of cerebellum is feasible using rFOV or zoomed MRSI at 3T.
- Citations
- 0
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Quantitative metabolic reference for healthy human cerebrum derived from group averaged 9.4T 1H MRSI data
Andrew Martin Wright, Theresia Ziegs, A Henning·bioRxiv·Apr 4, 2024
- Whole-Brain High-Resolution Metabolite Mapping with 3D Compressed-Sensing-SENSE-LowRank 1H FID-MRSI
Antoine Klauser, Paul Klauser, … François Lazeyras·NMR in BiomedicinePeer-reviewed·Oct 1, 2021
- Downfield Proton MRSI with whole-brain coverage at 3T
I. Ozdemir, S. Ganji, … P. B. Barker·bioRxiv·Jan 27, 2023
- Achieving High-Resolution Whole-Brain Slab 1H-MRSI with Compressed-Sensing and Low-Rank Reconstruction at 7 Tesla
Antoine Klauser, Bernhard Strasser, … Ovidiu C. Andronesi·Journal of Magnetic ResonancePeer-reviewed·Aug 11, 2021
- Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. Bhogal, Tommy A.A. Broeders, … Jannie P. Wijnen·Brain and BehaviorPeer-reviewed·Nov 20, 2020
- Cerebellar Ex Vivo Magnetic Resonance Imaging at its Feasibility Limit: Up to 77-Microns Isotropic Resolution using Low-Bandwidth Balanced Steady State Free Precession (LoBa-bSSFP) Sequences and 3T Standard Equipment
Matthias Weigel, Peter Dechent, … Cristina Granziera·bioRxiv·Apr 18, 2024