bioRxivBioengineering
Downfield Proton MRSI with whole-brain coverage at 3T
I. Ozdemir, S. Ganji, J. Gillen, S. Etyemez, M. Povazan, P. B. Barker
Abstract
PurposeTo develop a 3D downfield magnetic resonance spectroscopic imaging (DF-MRSI) protocol with whole brain coverage and post-processing pipeline for creation of metabolite maps. MethodsA 3D, circularly phase-encoded version of the previously developed 2D DF-MRSI sequence with [Formula] spectral-spatial excitation and frequency selective refocusing was implemented and tested in 5 healthy volunteers at 3T. Downfield metabolite maps with a nominal spatial resolution of 0.7 cm3 were recorded in 8 slices at 3T in a scan time of 22m 40s. An MRSI post-processing pipeline was developed to create DF metabolite maps. Metabolite concentrations and uncertainty estimates were compared between region differences for nine downfield peaks. ResultsLCModel analysis showed CRLB average values of 3-4% for protein amide resonances in the three selected regions (anterior cingulate (ACC), dorsolateral prefrontal cortex (DLPFC), and centrum semiovale (CSO)); CRLBs were somewhat higher for individual peaks but for the most part were less than 20%. While DF concentration maps were visually quite homogeneous throughout the brain, general linear regression analysis corrected for multiple comparisons found significant differences between CSO and DLPFC for peaks at 7.09 ppm (p= 0.014), 7.90 ppm (p=0.009), 8.18 ppm (p=0.009), combined amides (p=0.009), and between ACC and DLPFC for the 7.30 ppm peak (p=0.020). CRLB values were not significantly different between brain regions for any of the DF peaks. Conclusion3D DF-MRSI of the human brain at 3T with wide spatial coverage for the mapping of exchangeable amide and other resonances is feasible at a nominal spatial resolution of 0.7 cm3.
Reproducibility ledger
Nobody has reported trying to reproduce this paper yet. Did you replicate an experiment or run the code? Your report saves the next lab a week.
Sign in to file a reproducibility report.
Related papers
- Whole-Brain High-Resolution Metabolite Mapping with 3D Compressed-Sensing-SENSE-LowRank 1H FID-MRSI
Antoine Klauser, Paul Klauser, … François Lazeyras·NMR in BiomedicinePeer-reviewed·Oct 1, 2021
- Lipid suppressed and tissue-fraction corrected metabolic distributions in human central brain structures using 2D 1H Magnetic Resonance Spectroscopic Imaging at 7 tesla
Alex A. Bhogal, Tommy A.A. Broeders, … Jannie P. Wijnen·Brain and BehaviorPeer-reviewed·Nov 20, 2020
- Quantitative metabolic reference for healthy human cerebrum derived from group averaged 9.4T 1H MRSI data
Andrew Martin Wright, Theresia Ziegs, A Henning·bioRxiv·Apr 4, 2024
- High-Resolution Metabolic Mapping of the Cerebellum Using a Reduced Field of View (Zoomed) Magnetic Resonance Spectroscopic Imaging
Uzay E. Emir, Jaiyta Sood, … Sean P. Lane·bioRxiv·May 20, 2020
- Quantitative 2D J-resolved metabolite-cycled semiLASER spectroscopy of metabolites and macromolecules in the human brain at 9.4 T
Saipavitra Murali‐Manohar, Tamás Borbáth, … A Henning·bioRxiv·Sep 30, 2024
- Quantitative T1-relaxation corrected metabolite mapping of 12 metabolites in the human brain at 9.4 T
Andrew Martin Wright, Saipavitra Murali‐Manohar, A Henning·NeuroImagePeer-reviewed·Sep 1, 2022